WOLF 2MS INSTALLATION NOTE AND FIRST STEP
| WOLF 2MS INSTALLATION NOTE AND FIRST STEP
31
11
WOLF 2MS INSTALLATION NOTE AND FIRST STEP
Best setup location
The Wolf 2MS
should be installed in a 19” rack. Avoid direct sunlight, close proximity to radiators and air conditioning,
dust, water, and chemicals. Choose a rack location that permits a clear view to the indicators on the device and ensure a
sufficient heat dissipation of the device.
Power supply
The device is designed for operation with 100 to 240 V AC, 50 Hz to 60 Hz. Check the corresponding device labelling for
compatibility to the domestic line voltage and frequency before connecting the IEC power connector to the mains supply!
WARNING
Disconnect mains power plug before you
open the housing. Repair of the equipment
must only be carried out by authorized and
qualified personnel.
1
Power Supply
Please make sure that the device and the contained fuse(s) (please see
p. 20) are compatible to the domestic line voltage and frequency. If the
device is compatible, connect the power supply cord fully to the IEC
power connector at the rear side of the device and a mains power
outlet.
The “LCD Screed” will then turn on.
2
Network configuration
For delivery, the device is configured with default settings for the first
connection via the IP interface.
Wolf 2MS have a display, so you can configure the IP settings right
now:
See step
“
LAN-1 Page Functionality (How to set the TCP/IP ETH-1)
”
3
Connect to network
Connect a network patch cable to the “10/100-Base-T” connector on the
rear side of the device and your existing IP network.
4
Web interface
The device can be fully operated with an internet browser via the
integrated web interface. Use a computer that is connected to the same
IP network that the Wolf 2MS device is connected to. Start an internet
browser, Firefox/Mozilla >V2.0 Google Chrome both with Java Script
activated and enter the configured IP address in the address bar of the
browser. If the IP address has not been changed in step 2, please enter
the default address in the address bar of the browser:
192.168.XXX.XXX.
5
Connect FM antenna
cable to each Tuner-1
and Tuner-2
Now connect the antenna cable to Wolf 2MS. There are two separate
BNC inputs, please provide a correct level of RF signal to the
equipment. See in the technical specs the RF level range.
6
Ready!
These first steps are only intended for a quick first start and do not
cover all device functions. Pease read carefully the entire manual to be
able to use all functions of the device.
7
Important note on the
Username and password
The equipment comes out from Axel Technology with a standard
username: admin and password: admin
Each time a NEW user, with administration rights is created, the user
admin
disappear and it is replaced by the new one just created. If all
users are deleted, the standard admin
– admin comes out again
Содержание WOLF 1MS
Страница 1: ...WOLF 1MS WOLF 2MS User Manual FM monitoring system and streaming device Rev 1 3...
Страница 10: ...ENG GENERAL DESCRIPTION 10...
Страница 11: ...ENG GENERAL DESCRIPTION 11...
Страница 12: ...ENG GENERAL DESCRIPTION 12...
Страница 14: ...ENG GENERAL DESCRIPTION 14 WOLF 1MS WEB PAGE...
Страница 15: ...ENG GENERAL DESCRIPTION 15 WOLF 2MS WEB PAGE...
Страница 16: ...ENG GENERAL DESCRIPTION 16 WOLF 1MS WOLF 2MS BLOCK DIAGRAM...
Страница 78: ...78 Example 3 RFL2 MASK This schemes shows from left to right the flow of each single Alarm...
Страница 216: ...TECHNICAL APPENDIX TECHNICAL APPENDIX 216...
Страница 218: ...TECHNICAL APPENDIX TECHNICAL APPENDIX 218...
Страница 221: ...TECHNICAL APPENDIX TECHNICAL APPENDIX 221...