TECHNICAL APPENDIX
| TECHNICAL APPENDIX
199
16.11.18
RDS BLER Data test (Tuner-1 Tuner-2)
This test checks alarms and traps on BLER of a Radio tuned on frequency 100.5MHz.
The test was carried out on both tuners.
The system can monitor Rds data Block Error Rate (Bler) as signal quality expressed as percents.
For the Static Mode test we set Max Bler=10% and an Hysteresis=5%, Validation Time=10 sec. and Hold Time=15 sec.
Under the alarm condition the RDS alarm led on (we have associated the Bler alarm to the panel led Rds error) on the
panel must be on (not flashing) and clicking on the channel number of the correspondent tuner the RDS error will be
displayed (“RDS DATA”).
Tested in Scan mode with 3 frequencies:
F1: 100.5 MHz
F2: 95.3 MHz
F3: 96.7 MHz
and Timeout=20 sec. - Hold Time=15 sec. as depicted below.