101
14.6.20
Audio MS (Mono Silence)
This page allows the user to set mainly the silence threshold and timing, for Audio Mono inside MPX Signal.
Mono Silence alarm and about 16 new Oids in the Audio Module branches and two new traps. This new alarm rises up
when the audio levels “(RightRms)/2” is under the threshold for a time greater than the silence time. The
threshold range is down to -60dBr. The measurement value is available with all input sources, but the alarms and traps
are available for the Tun1 e Tun2 sources only. MIB L4-0 is required
NAME
DESCRIPTION
NOTE
Chan
Channel Number
Chan Label
Mnemonic name that can be applied to the Channel / Frequency
Frequency
Frequency corresponding to the Channel, expressed in MHz
Preset
String used by the configurator
Scan Time
This value represents the time in s that the tuner remain on this frequency.
Chan Mask
This control allow (or not) the channel to be under control.
Thr
This is the minimum level to be considered
audio
. Under this threshold the audio is
considered “silence”.
Time
This parameter is related to Silence Thr, after this <Validation> the incoming audio
is considered “Silence”
Hold
is the time between the cessation of the alarm condition and alarm signaling finished
Mask
It is possible to set, for each single parameter: unmasked, masked, severity-1,
severity-2, severity-3, RFL2 mask.
Email
In case the alarm/error raise up, the Wolf 2MS sends an email if <enable>.
If is <disable> no action are taken.
Trap
In case the alarm/error raise up, the Wolf 2MS sends a trap if <enable>.
If is <disable> no action are taken.
Label
This is the label/content that the user can choose to shows via email or in the trap in
case of error.
Содержание WOLF 1MS
Страница 1: ...WOLF 1MS WOLF 2MS User Manual FM monitoring system and streaming device Rev 1 3...
Страница 10: ...ENG GENERAL DESCRIPTION 10...
Страница 11: ...ENG GENERAL DESCRIPTION 11...
Страница 12: ...ENG GENERAL DESCRIPTION 12...
Страница 14: ...ENG GENERAL DESCRIPTION 14 WOLF 1MS WEB PAGE...
Страница 15: ...ENG GENERAL DESCRIPTION 15 WOLF 2MS WEB PAGE...
Страница 16: ...ENG GENERAL DESCRIPTION 16 WOLF 1MS WOLF 2MS BLOCK DIAGRAM...
Страница 78: ...78 Example 3 RFL2 MASK This schemes shows from left to right the flow of each single Alarm...
Страница 216: ...TECHNICAL APPENDIX TECHNICAL APPENDIX 216...
Страница 218: ...TECHNICAL APPENDIX TECHNICAL APPENDIX 218...
Страница 221: ...TECHNICAL APPENDIX TECHNICAL APPENDIX 221...