WOLF 2MS GENERAL DESCRIPTION
| WOLF 2MS GENERAL DESCRIPTION
42
12.4.7
Alarms Panel Zone Functionality
This Label shows the status of the Alarms panel
This Label shows the status of the Alarms panel
Right LCD Panel
Left LED Panel (Alarm Panel)
The Alarms Panel
(Left LED Panel)
shows:
-
on the left side the alarms of Tuner module-1
-
on the right side the alarms of Tuner module-2
In the Right LCD Panel it is possible to find the Alarm Panel label (red square in the picture above) The status of this
label should be:
AC
All Channels - Mode
In AC Mode the LEDs indicate the OR (sum) of the all
same alarm type when the LEDs are on theirs status is
blinking.
SC
Single Channel - Mode
In SC Mode the LEDs indicate only the alarm of the
memory and frequency selected, when the LEDs are on
theirs status is fixed.
This label shows the status of the two areas of alarms panel :
-
Label
AC-AC
(Tuner-1 and Tuner 2 are in All Channels - Mode)
-
Label
SC-SC
(Tuner-1 and Tuner 2 are in Single Channel - Mode)
-
Label
AC-SC
(Tuner-1 is in All Channels - Mode and Tuner 2 is in Single Channel - Mode)
-
Label
SC-AC
(Tuner-1 is in Single Channel - Mode and Tuner 2 is in All Channels - Mode)
Check the display functionality and
RF ALARM
Status:
-
Using web page set SCAN mode for the 1
st
and 2
nd
tuner.
-
Verify the display status :
AC-AC
-
Using web server move the RF-H1 threshold of the first memory under the measured value for each tuner.
-
Verify that the display shows TUNER ERROR, in memory 01 for each tuner.
-
The first led
RF ALARM
is blinking for each tuner.
-
Using the the Jog Shuttle move the cursor on the display under the tuner-1 memory number.
-
Push the Jog Shuttle (To select the function)
-
Rotate the Jog Shuttle till to set Memory 01
-
Verify the display status : SC-AC
-
The first led RF ALARM of Tuner-1 is fixed
-
The first led RF ALARM of Tuner-2 is blinking
-
Using the the Jog Shuttle move the cursor on the display under the tuner-2 memory number.
-
Push the Jog Shuttle (To select the function)
-
Rotate the Jog Shuttle till to set Memory 01
-
Verify the display status : SC-SC
-
The first led RF ALARM of Tuner-1 is fixed
-
The first led RF ALARM of Tuner-2 is fixed
Содержание WOLF 1MS
Страница 1: ...WOLF 1MS WOLF 2MS User Manual FM monitoring system and streaming device Rev 1 3...
Страница 10: ...ENG GENERAL DESCRIPTION 10...
Страница 11: ...ENG GENERAL DESCRIPTION 11...
Страница 12: ...ENG GENERAL DESCRIPTION 12...
Страница 14: ...ENG GENERAL DESCRIPTION 14 WOLF 1MS WEB PAGE...
Страница 15: ...ENG GENERAL DESCRIPTION 15 WOLF 2MS WEB PAGE...
Страница 16: ...ENG GENERAL DESCRIPTION 16 WOLF 1MS WOLF 2MS BLOCK DIAGRAM...
Страница 78: ...78 Example 3 RFL2 MASK This schemes shows from left to right the flow of each single Alarm...
Страница 216: ...TECHNICAL APPENDIX TECHNICAL APPENDIX 216...
Страница 218: ...TECHNICAL APPENDIX TECHNICAL APPENDIX 218...
Страница 221: ...TECHNICAL APPENDIX TECHNICAL APPENDIX 221...