
TECHNICAL APPENDIX
| TECHNICAL APPENDIX
197
16.11.17
RDS EON Data test (Tuner-1 Tuner-2)
This test checks alarms and traps on EON of a Radio tuned on frequency 100.5MHz.
The test was carried out on both tuners.
The system can monitor EON presence on tuned radio.
In this test branch Tuned radio has no EON.
For the Static Mode test we set Timeout=20 sec. and Hold Time=15 sec.
Under the alarm condition the RDS alarm led on (we have associated the EON alarm to the panel led Rds error) on the
panel must be on (not flashing) and clicking on the channel number of the correspondent tuner the RDS error will be
displayed (“RDS DATA”).
Tested in Scan mode with 3 frequencies:
F1: 100.5 MHz
F2: 95.3 MHz
F3: 96.7 MHz
and Timeout=20 sec. - Hold Time=15 sec. as depicted below.
Содержание WOLF 1MS
Страница 1: ...WOLF 1MS WOLF 2MS User Manual FM monitoring system and streaming device Rev 1 3...
Страница 10: ...ENG GENERAL DESCRIPTION 10...
Страница 11: ...ENG GENERAL DESCRIPTION 11...
Страница 12: ...ENG GENERAL DESCRIPTION 12...
Страница 14: ...ENG GENERAL DESCRIPTION 14 WOLF 1MS WEB PAGE...
Страница 15: ...ENG GENERAL DESCRIPTION 15 WOLF 2MS WEB PAGE...
Страница 16: ...ENG GENERAL DESCRIPTION 16 WOLF 1MS WOLF 2MS BLOCK DIAGRAM...
Страница 78: ...78 Example 3 RFL2 MASK This schemes shows from left to right the flow of each single Alarm...
Страница 216: ...TECHNICAL APPENDIX TECHNICAL APPENDIX 216...
Страница 218: ...TECHNICAL APPENDIX TECHNICAL APPENDIX 218...
Страница 221: ...TECHNICAL APPENDIX TECHNICAL APPENDIX 221...