Configuring Voicemail Pro
Voicemail Pro Installation and Maintenance Guide
Page 109
IP Office
15-601063 Issue 15b (31 May 2006)
Setting Up Disk Space and Recording Time Alarms
The IP Office system can be configured to send Simple Network Management Protocol (SNMP) alarms.
When this is configured, the Voicemail Pro server can tell the IP Office system when to send SNMP
alarms about available disk space and remaining recording time.
To set up disk space and recording time alarms:
1. Display the main Voicemail Pro window.
2. From the Administration menu, select Preferences.
3. From the Preferences submenu, select General.
4. Click the SNMP Alarm tab.
5. Choose the Alarm Threshold Unit
Choose either Disk Space Left (MB) or Recording Time left (minutes).
6. In the Alarm Threshold Level box, type the number of units (minutes or MB) left at which SNMP
alarms are to be triggered. The minimum is 11. This value also sets two further SNMP alarm
levels which are:
Space OK Alarm : This alarm is triggered when the amount of available space returns to
above a level set at Alarm Threshold Level plus 30.
Critical Alarm : This alarm is set at 30 or, when the Alarm Threshold Level is less than
40, at Alarm Threshold Level minus 10. Currently the critical alarm value will decrease in
accordance with the above rule. Note however that it does not increment upwards when
the Alarm Threshold is increased again. To reset the critical alarm back to 30, click
Default Settings.
7. To return to the default alarm settings, click Default Settings.
The Alarm Threshold Level is reset to 60. The Space OK level is reset to 90. The Critical Alarm
level is reset to 30.