7.2.
Indication lights/LEDs
The indication lights/LEDs locally display the different operation states as
optical signals. The assignment of signals is freely selectable.
Figure 25 shows the indication lights/LEDs on the local controls:
Table 5 describes the standard indication.
Information
The behaviour (blinking/illuminated) can be changed via the
BLINKER
parameter.
7.3.
Mechanical position indicator/running indication (option)
Mechanical position indicator
.
continuously indicates the valve position
(Indicator disc rotates approximately 180° to 230° at full travel from
OPEN to CLOSED or vice versa.)
.
indicates whether the actuator is running (running indication)
.
indicates that the end positions (via indication mark) have been reached
36
Multi-turn actuator SAExC 07.1 – SAExC 16.1/SARExC 07.1 – SARExC 16.1 Non-Intrusive
with actuator controls AUMATIC ACExC 01.1 Profibus DP
Operation instructions
LED 1 (left)
(
symbol)
illuminated
Actuator is in end position CLOSED
blinking
Running indication: Actuator runs in direction
CLOSE
LED 2 (T)
illuminated
Torque fault CLOSE
LED 3 (Th)
illuminated
Motor protection tripped
LED 4 (T)
illuminated
Torque fault OPEN
LED 5 (right)
(
symbol)
illuminated
Actuator is in end position OPEN
blinking
Running indication: Actuator runs in direction
OPEN
Table 5
Figure 25
auma
2
3
5
4
1
Figure 26
Version (standard):
Version (option):
LED marking with letters
LED marking with figures
1
Cover
4
Symbol for position OPEN
2
Indicator disc
5
Symbol for position CLOSED
3
Indicator mark