9.9.
Switch compartment: close
1. Clean sealing faces of housing and cover.
2. Apply a thin film of non-acidic grease (e.g. Vaseline) to the sealing faces.
3. Preserve joint surfaces with an acid-free corrosion protection agent.
4. Check whether O-ring (3) is in good condition, correctly insert O-ring.
5. Place cover (1) on switch compartment.
6. Fasten screws (2) evenly crosswise.
56
Multi-turn actuator SAExC 07.1 – SAExC 16.1/SARExC 07.1 – SARExC 16.1 Non-Intrusive
with actuator controls AUMATIC ACExC 01.1 Profibus DP
Operation instructions
Danger of corrosion due to damage to paint finish!
Ò
Touch up damage to paint finish after work on the device.
NOTICE