Identification data for explosion-proof version:
1 Approved mark (in our example: CENELEC)
2 Explosion protection classification - electrical explosion protection
a) Equipment group (mining industry I, other areas II)
b) Category 2 (for zone I)
c) Medium (G = gas or D = dust)
d) Area of standards application (E for European Standard)
e) Explosion-protected electrical equipment
f) Protection types (here flameproof enclosure and increased safety)
g) Explosion group
h) Temperature class
3 EC type examination certificate
4 Explosion protection classification - non-electrical explosion protection
a) see above
b) Protection type (here constructional safety)
c) see above
Type and size
These instructions apply to the following actuator controls combinations:
Type: SAExC = multi-turn actuator for open-close duty
Type: SA
R
ExC = multi-turn actuator for modulating duty
Size: 07.1 – 16.1
Version: Non-Intrusive
Type: ACExC = AUMATIC actuator controls
Size: 01.1
Commission number
An order-specific commission number is assigned to each device. You can
use this commission number to download inspection records and further
information for the device from the Internet (
http://www.auma.com
).
Wiring diagram/control
The actuator controls are designed for the
Non-Intrusive
version (refer also
to page 9), if the 7th position in the ACP wiring diagram contains the letter
M, e.g.: ACP E3FC-2
M
0—S000.
Controlling the actuator controls is performed via a
Profibus DP interface
,
if the 11th position in the ACP wiring diagram contains the letter S, T, U, R,
or P. Example: ACP E3FC-2M0—
S
000.
8
Multi-turn actuator SAExC 07.1 – SAExC 16.1/SARExC 07.1 – SARExC 16.1 Non-Intrusive
with actuator controls AUMATIC ACExC 01.1 Profibus DP
Operation instructions
II 2 G EEx de IIC T4
a
c
e
g
b
d
f
h
II 2 G c IIC T4
a
c
b
auma
CC
0102
Riester GmbH & Co.KG
D-79379 Muellheim
II2G EEx de IIC T4
PTB 01 ATEX 1087
2IIG c IIC T4
1
2
3
4
Figure 4