4.4.
Mounting positions of the local controls
The mounting position of the local controls is designed according to the
order. If, after mounting the actuator to the valve or the gearbox on site, the
local controls is in an unfavourable position, the mounting position can be
changed at a later date. Four mounting positions are possible.
Figure 9 shows mounting positions A and B:
Figure 10 shows mounting positions C and D:
Changing the mounting position
1. Loosen bolts and remove the local controls.
2. Check whether O-ring is in good condition, correctly insert O-ring.
3. Turn local controls into new position and re-place.
4. Fasten bolts evenly crosswise.
16
Multi-turn actuator SAExC 07.1 – SAExC 16.1/SARExC 07.1 – SARExC 16.1 Non-Intrusive
with actuator controls AUMATIC ACExC 01.1 Profibus DP
Operation instructions
Figure 9
Figure 10
Flameproof enclosure, danger of explosion!
Risk of death or serious injury.
Ò
Before opening, ensure that there is no explosive gas and no voltage.
Ò
Handle cover and housing parts with care.
Ò
Joint surfaces must not be damaged or soiled in any way.
Ò
Do not jam cover during fitting.
Cable damage due to twisting or squeezing!
Functional failures possible.
Ò
Turn local controls by a maximum of 180°.
Ò
Carefully assemble local controls to avoid pinching the cables.
NOTICE
DANGER