365
Set Command Library
PWR,OFF: Powering Off the Receiver
Function
This command is used to power off the receiver.
Command Format
Syntax
$PASHS,PWR,OFF[*cc]
Parameters
None.
Example
Turning off the receiver:
$PASHS,PWR,OFF*43
Relevant Query
Command
None.
PWR,PAR: Power Management
Function
This command is used to set the voltage thresholds triggering
low-power alarms and to set the lower and upper limits of
power voltage for which the receiver will be powered on or off
automatically if the DC voltage applied to the external power
input is respectively within or out of these limits (making this
second function operational requires that the slide switch
located at the bottom of the compartment be pushed to the
right).
Command Format
Syntax
$PASHS,PWR,PAR,f1,f2[,[f3],[f4]][*cc]
Содержание HDS800
Страница 1: ...Reference Manual HDS800...
Страница 16: ...x Enabling a Firmware Option 639 Decoding an NTRIP Source Table 639 Logging Raw Data 642...
Страница 54: ...38 Receiver Description...
Страница 104: ...88 Using the Web Server...
Страница 161: ...145 Web Server Help Files Collection Configuration Tab These groups of parameters are detailed below...
Страница 189: ...173 Web Server Help Files Collection Configuration Tab...
Страница 250: ...234 Ethernet Connection dd is the day number 1 31 when the file was created The file extension is log...
Страница 266: ...250 Using Serial Commands...
Страница 606: ...590 Query Command Library...
Страница 619: ...603 Data Output...
Страница 628: ...612 Data Output...
Страница 650: ...634 Troubleshooting...
Страница 660: ...644 Other Procedures Memos...
Страница 676: ...X XDR 110 112 587 Z Z Blade 1 ZDA 347 431 588...
Страница 677: ......