Connection Lost Timeout
is the number of seconds to wait before declaring the connection lost. The exact
conditions for timeout vary according to the IPRC method. Default setting is 60 seconds.
Alcatel OmniPCX
, this setting determines the number of seconds the client will wait before timing out. A
timeout will occur if the client has not received any data (either ticket data or any protocol control data) from
the switch in the amount of time set forth here. This timeout value can be set from 45 to 90 seconds.
Avaya Definity RSP
, this event is triggered when either the socket or the session is down. With RSP, there is
an application-layer connection called a Session that runs on top of the lower-layer socket. It is possible that
the socket is established but the session is not. RSP will not run if the session is not established. This
timeout can be set from 3 to 600 seconds.
Generic Server
does not use any application layer protocols so the socket lost timeout is triggered only by
the loss of the TCP connection. This timeout can be set from 3 to 600 seconds.
Connection Lost Alarm Actions
displays a list of actions from which the action(s) to be taken for this alarm are
configured. This field will be empty [ ] if no actions have been configured. Refer to
for more information.
Connection Lost Alarm Message
sets the text string to be delivered with this event’s action. Default setting is
Connection Lost.
Upon timeout, an Alcatel OmniPCX client disconnects and will attempt to reconnect in 10 seconds. The
timeout value is restricted between 45 and 90 seconds. Once the alarm is activated, the alarm will not re-arm
until a socket connection is re-established. Avaya RSP and Generic Server are passive TCP servers and
cannot attempt to reconnect to the client. They must wait for the client to reestablish the connection.
Alarm Class
sets the class for the event. When this option is selected, a list of the classes previously defined in the
is displayed, from which you can select one to be assigned to this event.
Trap Number
sets the number to be sent with any SNMP traps for this event. Default is 508, but trap number can
also be set in the range of 1000
– 1199 as needed.
Serial Handshaking Alarm Settings
Serial Handshaking Alarms allows the T850 to monitor each of its serial ports and alert you if the DTR signal from the
connected devices drops low. This would be an indicator that the connected device has failed, the cable between the
T850 and the device has been disconnected, or a number of other reasons depending on the device. It can also alert
you when the DTR signal goes high again.
TeleBoss 850 - Serial Handshaking Alarm Settings
A) I/O 1 Serial Handshaking Alarms [OFF]
B) I/O 2 Serial Handshaking Alarms [OFF]
I/O
n
Serial Handshaking Alarms
displays a menu for configuring alarming on serial DTR handshaking conditions.
TeleBoss 850 - I/O 1 Serial Handshaking Alarms
A) Serial Handshaking Low Alarm Enable [OFF]
B) Serial Handshaking Low Alarm Actions []
C) Serial Handshaking Low Alarm Message [Handshake Low]
D) Serial Handshaking Low Alarm Class [Info]
E) Serial Handshaking Low Trap Number [510]
F) Serial Handshaking High Alarm Enable [OFF]
G) Serial Handshaking High Alarm Actions[]
H) Serial Handshaking High Alarm Message[Handshake High]
I) Serial Handshaking High Alarm Class [Info]
J) Serial Handshaking High Trap Number [510]