TeleBoss 850 2.06.280_STD User Manual
Page 14
Getting Connected
Power Up Sequence
On startup, the T850 goes through the following boot sequence in approximately 55 seconds:
1) The power LED flashes once each second for 30 seconds.
2) The LED for Expansion Card 1 go through a 15 second flashing sequence.
3) All LED’s then go off for approximately 5 seconds.
4) Power, Modem (if installed) and Ethernet LEDs light for 5 seconds, then Modem and Ethernet go off.
5) Power LED will blink once every 5 seconds as a "heartbeat" while the T850 is powered on.
Default Passwords
The T850 uses a very flexible system for managing users, passwords, and access rights. By default, the following
fifth user profiles are enabled. Note that if a password is defined without a user name, the profile is defined just by the
user name. All of the default profiles are password-only. All passwords are masked: ********
The default settings are configured to low security for your convenience in setup. It is highly recommended that you
change these passwords and record them in a secure location.
User
Password
Login To
User1
SMDR
Command processor
User2
SUPER
Command processor
User3
ACCESS1
Passthrough/File 1
User4
ACCESS2
Passthrough/File 2
User 11
Username: admin
Password: password
Command processor
The Status Screen
The T850 Status screen is the unit's one-stop informational source. Most of the information that a user would need to
know about the unit is available through this display. This section outlines this data and highlights why it is useful.
TeleBoss 850 2.06.280 STD - Status
Site Name : 850-850000163
Serial Number : 850000163 Eth 1 : STATIC
Date : THU 03/03/2011 IP Addr : 0.0.0.0
Time : 08:02:48 MAC Addr : 00:10:A3:60:02:3E
Memory : 32768K Eth 2 : STATIC
% Full Alarm : OFF IP Addr : 0.0.0.0
No-Data Alarm 1 : OFF MAC Addr : 00:10:A3:60:02:3F
No-Data Alarm 2 : OFF Modem : Yes
Duplex : FULL
-------------------------------------------------------------------------
Port Baud/Etc. Recs Bytes Full Wrap Name
IO1 : 19200,8N1 00000000 00000000 0% OFF I/O 1
IO2 : 19200,8N1 00000000 00000000 0% OFF I/O 2
COMPLETE
>
TeleBoss 850
indicates that this product is the T850, followed by
2.06.280 STD,
the currently loaded firmware
version.
Site Name
is the identifier assigned to each T850 by the end user in the General Settings menu.
Serial Number
is the factory-assigned, unique serial number for this T850.