![Asentria Teleboss 850 Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/asentria/teleboss-850/teleboss-850_user-manual_2981745010.webp)
TeleBoss 850 2.06.280_STD User Manual
Page 4
Web
opens an HTTP connection to the device using your default browser, if the device supports and is
configured to allow a web connection.
3. Once the network settings have been assigned, the T850 command line can be accessed via any Telnet client or
HTTP web connection.
Contact
for any questions or assistance with OmniDiscover.
Network Setup
via OmniDiscover connection:
1. See the description of how to use
via serial connection:
1. Access the Main Setup Menu by typing
SETUP
and pressing <Enter>.
2. Select the Network Settings branch.
3. Select A) Ethernet Settings and select the Ethernet interface that corresponds to the one on the back panel that
you plugged your network cable into.
4. Enter an IP address, subnet mask and--if necessary--a router address.
5. Toggle NAT on/off as desired.
6. If using this Ethernet interface for a VLAN connection, select this option to configure any of six VLAN connections.
section in the Features chapter for details on how to configure.
7. Press <ESC> to go back one level in the menu tree, or <CTRL + C> to exit the Main Setup Menu and return to
the command prompt.
Testing Network Connectivity
1. Verify that the network router is available to the unit by typing the command
PING <
IP_address
>
. A router is
always a good candidate to test pings. The following screenshot is an example of a successful ping test.
ping 192.168.100.59
PING 192.168.100.59 (192.168.100.59): 56 data bytes
64 bytes from 192.168.100.59: icmp_seq=0 ttl=128 time=8.0 ms
64 bytes from 192.168.100.59: icmp_seq=1 ttl=128 time=0.7 ms
64 bytes from 192.168.100.59: icmp_seq=2 ttl=128 time=1.8 ms
64 bytes from 192.168.100.59: icmp_seq=3 ttl=128 time=0.8 ms
64 bytes from 192.168.100.59: icmp_seq=4 ttl=128 time=0.7 ms
64 bytes from 192.168.100.59: icmp_seq=5 ttl=128 time=0.7 ms
--- 192.168.100.59 ping statistics ---
6 packets transmitted, 6 packets received, 0% packet loss
round-trip min/avg/max = 0.7/1.7/8.0 ms
2. Press <CTRL + C> to stop the ping testing. If <CTRL + C> is not pressed, the unit will continue pinging attempts
indefinitely.
3. If there is an error message or no response from the router, first check the network settings and connection, then
consult your System Administrator or
4. Using a Telnet client, connect to the IP address assigned to the unit.
SNMP Trap Setup
If you will be using your T850 to send SNMP traps, this section will help you ensure it is set up correctly.
Setup
1. Configure the network settings as described in the previous section.
2. Select the Network Settings then SNMP Settings sub-menu.
3. Verify the SNMP Community name is correct for your network.
4. Switch to the
menu and enter the Hostname or IP address of the computer to receive the traps
into the field, “Hostname/IP Address 1”.