TeleBoss 850 2.06.280_STD User Manual
Page 141
30
Segments-Rate 2
368-377
10
R
31
Segments-Rate 3
378-387
10
R
32
Com Type
388
1
NA
33
X25 In Flow Rate
389-390
2
R
34
X25 Out Flow Rate
391-392
2
R
35
Carrier
393-394
2
R
36
Initial Dialed Number
395-424
30
L
37
Waiting Duration
425-429
5
R
38
Effective Call Duration
430-439
10
R
39
Redirected Call Indicator
440
1
NA
40
Start Date-time
441-457
17
NA
41
Acting Extension Number
458-487
30
L
42
Called Number Node
488-492
5
R
43
Calling Number Node
493-497
5
R
44
Initial Dialed Number Node
498-502
5
R
45
Acting Extension Number Node 503-507
5
R
46
Transit Trunk Group ID
508-512
5
R
47
EndOfLine (0x0A)
513
1
NA
The Real Time Client
The client is idle whenever there are no configured OmniPCX settings. After you upload a configuration file for the
first time, type "
IPRC START
" to start the client. Then type "
IPRC STATUS
" or "
IPRC ?
" to check the current status.
It will either indicate a working status (e.g., "Established - awaiting packet") or if something is wrong (e.g., unable to
connect to the OmniPCX, or a certain output field definition doesn't make sense). All output field definitions must
compile correctly in order for the unit to accept the configuration and attempt to connect to the OmniPCX.
Once the client has accepted a valid configuration, it will attempt to connect to the OmniPCX whenever the unit is
reset. If the user manually stops the client with the
IPRC STOP
command, then the client will remain in the idle state
until either the unit is reset or the user enters the
IPRC START
command.
If a new configuration is uploaded while the client is connected to the PBX, then it will:
1. Disconnect from the PBX if the configuration is invalid.
2. Stay connected to the PBX using the new configuration, if the configuration is valid and the PBX IP address or
TCP port did not change.
3. Disconnect from the PBX and reconnect using the new configuration, if the configuration is valid and the PBX IP
address or TCP port changed.