![Asentria Teleboss 850 Скачать руководство пользователя страница 154](http://html.mh-extra.com/html/asentria/teleboss-850/teleboss-850_user-manual_2981745154.webp)
TeleBoss 850 2.06.280_STD User Manual
Page 148
Intecom Telari
Definition
Intecom Telari is IPRC from EADS (f.k.a. Intecom) E and Telari switches. In this method of IP record collection, a
TCP/IP client on the unit attempts connections and accepts CDR via the connection. This method of IPRC differs
from Generic Client in that it employs a proprietary application-layer protocol to transmit records.
Configuration:
TeleBoss 850 - IP Record Collection (IPRC) Setup
A) IP Record Collection [INTECOM TELARI]
B) Store Collected Data In [FILE1]
C) Data Alarm/Filter Enable [OFF]
D) Target Name [IPRC 1]
E) Hostname/IP Address []
F) Port [8186]
G) Connection Interval (minutes) [1]
H) Time Stamping [OFF]
IP Record Collection
sets the protocol to be used to Intecom Telari.
Store Collected Data In
toggles the FILE to which all incoming Syslog data will be stored. Options are FILE1, FILE2,
AUX1, AUX2, and AUX3. Default setting is FILE1.
Data Alarm/Filter Enable
is an ON/OFF toggle to set whether configured Data Alarms or Filters will be applied to the
incoming data. Default setting is OFF.
Target Name
is the name used to identify the switch when an IPRC Connection Lost Alarm is sent via an
AsentriaAlarm. Default setting is IPRC 1.
Hostname/IP Address
sets the hostname or IP Address of the Telari Record Collection Server (RCS).
Port
set the TCP port used by the Telari RCS. Default setting is port 8186.
Connection Interval (minutes)
sets the number of minutes (1
– 65535) to wait before disconnecting an idle
connection. Default setting is 1.
Time Stamping
is an ON/OFF toggle to set whether each individual call record is stamped with the Date and Time
received in the T850. Default setting is OFF.
Commands
Command
Function
IPRC
IPRC STATUS
IPRC ?
Displays a status report of the active IPRC mode.
IPRC Connect Forces the client to connect from a state where it's waiting to connect.
IPRC Start
Causes immediate connection to the server to retrieve any new records and to
resume regular checking. This command is only required if automatic connection
was previously stopped using the IPRC STOP command.
IPRC Stop
Disables automatic connection and terminates any open connection. Automatic
connection is re-enabled if the T850 is restarted.
Status Display
The IPRC command brings up a status report similar to the following report:
Intecom CDR Client
Status: Idle
Time now: 12/16 12:24:10
COMPLETE