48
15
technicaL data
• Advanced menu
Data
description
min.
max.
uom
notes
Language
Display language
--
--
--
Available languages: Italiano, English, Español, Português,
Français, Deutsch, Cesky, Polski, Русский, Hrvatski.
Unit of measurement
Display unit of measurement
--
--
--
Values that can be set: Metric, US, Metr. L/100 m
Section valves number
Number of section control valves in
the device
--
--
--
Values that can be set: 1 ÷ 7
Coverage
Coverage
0.00
9.99
Rows
Machine total coverage.
The data will be displayed by setting the coverage of each
boom section
Section 1 ÷ 7
--
--
Rows
Rows treated by each boom section
Valves
Boom section
--
--
--
Values that can be set:
2 ways - without calibrated backflow,
3 ways - with calibrated backflow
Automatic switch-off
Values that can be set:
No (P mode), Yes (M mode)
Pressure regulator
Values that can be set:
2 ways, 3 ways
Master
Values that can be set:
2 ways, 3 ways, None
Flowmeter
*
Type
--
--
--
Values that can be set: Disabled, Orion 4621xA0xxxx,
4621xA1xxxx, 4621xA2xxxx, 4621xA3xxxx, 462xxA4xxxx,
4622xA5xxxx, 4622xA6xxxx, Other...
Min. flowrate alarm
Disab.
999.9
Metric
L/100 m: l/min
Minimum rate for flowmeter correct operation
Disab.
320.00
US: GPM
Max. flowrate alarm
Disab.
999.9
Metric
L/100 m: l/min
Maximum rate for flowmeter correct operation
Disab.
320.00
US: GPM
Constant
1
32000
Metric
L/100m: pls/l
Data necessary to calculate the rate
US: pls/gal
Pressure sensor
Type
--
--
--
Values that can be set:
Disabled, 466113.200, 466113.500, Other...
Maximum pressure
0.1
150.0
Metric
L/100m: bar
Data necessary to determine the instantaneous pressure
1
2200
US: PSI
Delivery cal. sensor
Sensor used to calculate the output
--
--
--
Values that can be set:
Flowmeter, Pressure, Either
Tank level
Mode
--
--
--
Values that can be set:
Manual, Level Sensor, Filling flowmeter
The active option affects the entire configuration of the
tank level
Mode:
Manual
Tank capacity
1.0
10000.0
Metric
L/100m: l
--
US: gal
Minimum level alarm
(range value of tank
fluid)
1.0
10000.0
Metric
L/100m: l
Below this value the computer triggers an acoustic and
visual alarm
US: gal
Mode:
Filling flowmeter
Tank capacity
1.0
10000.0
Metric
L/100m: l
--
US: gal
Minimum level alarm
(range value of tank
fluid)
1.0
10000.0
Metric
L/100m: l
Below this value the computer triggers an acoustic and
visual alarm
US: gal
Type
--
--
--
Filling flowmeter model.
Values that can be set: Orion 462xxA4xxxx, 4622xA5xxxx,
4622xA6xxxx, Other...
Constant
1
32000
Metric
L/100m: pls/l
Datum necessary to calculate the rate
US: pls/gal
Minimum flowrate
10.0
30.0
Metric
L/100 m: l/min
Minimum rate for flowmeter correct operation
2.60
8.00
US: GPM
Maximum flowrate
100.0
600.0
Metric
L/100 m: l/min
Maximum rate for flowmeter correct operation
53.00
158.00
US: GPM
Rev counter
*
Constant
Disab.
999
Metric
L/100m
US: pls/turn
--
Minimum speed alarm
Disab.
10000
Metric
L/100m
US: rpm
Below this set value the computer triggers an alarm
Maximum speed alarm
Disab.
10000
Metric
L/100m
US: rpm
Above this set value the computer triggers an alarm
Foam marker
Foam marker operation
--
--
--
Values that can be set:
Manual, Semi-autom., Automatic
Pump Protector
Pump membrane break alarm
--
--
--
Values that can be set: Enabled, Disabled
TECHNICAL DATA
*
pls = pulse
turn = turn