WORK FUNCTIONS
12.5
F4 - Tank
(page 1)
Fig. 115
Tank level - Filling flowmeter mode
(Par. 10.9.2)
> Filling up
BRAVO 300S displays the tank capacity: the value has been set in advanced setup.
> Level
BRAVO 300S displays the quantity of fluid inside the tank, calculated according to the job data.
> Filled quantity
Start the filling pump and stop it at the end of the filling procedure.
When the filling flowmeter is connected, the display shows the filling data in real time.
ATTENTION! Maximum level reached
Stop the loading pump: you have reached the maximum capacity of the tank.
> Estimated quantity need*
Enter area to be sprayed. The display will show the quantity of fluid to be poured in the tank in order to
complete spraying the set area.
Fig. 116
Tank level - Level sensor mode
(Par. 10.9.3)
> Level
BRAVO 300S displays the real quantity of fluid inside the tank, detected by the level sensor.
> Filled quantity
Start the filling pump and stop it at the end of the filling procedure.
When the level sensor is connected, the display shows the filling data in real time.
> Estimated quantity need*
Enter area to be sprayed. The display will show the quantity of fluid to be poured in the tank in order to
complete spraying the set area.
*
See note on Page 41.
12.6
F4 - User setting
(page 2)
It accesses the
User setting
.
Fig. 117
Refer to Chap.11 User setting to correctly program all menu items.
Par.
10.9