26
ADVANCED SETUP
Par.9.3
Quick reset of
change
Menu item scrolling or
Data increase/decrease
Confirms access to menu
or data change
Quits the menu or
data changes
> Load/Save calibr.
: the level sensor calibration can be loaded or saved on SD card to reconfigure the device if necessary, solve problems, or configure
another Bravo 300S without having to repeat all operations.
After having completed the calibration and checked the sensor correct operation, we recommend to memorise the calibration on SD card.
Before any other operation, insert the SD card in its slot (par. 8.6).
Select
to save
Fig. 60
> Save to SD card
: select this option and press
OK
.
The confirmation message
Setup saved on SD (TANK.TKL)
is displayed at the end of the
saving procedure. Press
ESC
.
SD card not found!
Saving alarm: memory card not inserted.
Select
to load
Fig. 61
> Load from SD card
: select this option and press
OK
.
The confirmation message
Setup loaded from SD (TANK.TKL)
is displayed at the end
of the configuration. Press
ESC
.
SD card not found!
File not found!
(TANK.TKL)
configuration alarms:
• Memory card not inserted.
• The tank configuration
TANK.TKL
is not saved on the memory card.
> Recovered liquid count
: on this menu, indicate if the recovered liquid count is enabled.
Select
to enable
Fig. 62
If a tunnel multi-row sprayer is used, the recovered liquid count can be enabled during treatment.
The information will be available in the job data (Par. 12.2 F2 - Current job data (PAGE 1).
10.10
Rev counter
Select
one item
Fig. 63
Increase rotation speed!
Reduce rotation speed!
Speed alarms
Set the data of the RPM sensor (if installed in the system).
> Constant
: indicate the constant of the installed RPM sensor.
If the RPM sensor is not installed press
CRL
: in this case the display will show the
message
Disabled
; the alarms
Minimum speed alarm
and
Maximum speed alarm
(Fig. 63) will no longer be displayed
> Minimum speed alarm
> Maximum speed alarm
The speed alarms (minimum or maximum) activate when the measured RPM exceed the set limits.
The control is active only when the spraying is active (main switch ON).
10.11
Foam marker
Fig. 64
On this menu, select the foam marker operating mode
.
> Manual
The foam marker is controlled through the special keys (Par. 13.2).
> Semi-autom.
Main switch ON --> foam marker ON
Main switch OFF --> foam marker OFF
The special keys enable the desired side (Par. 13.2).
> Automatic
Main switch ON --> foam marker ON
Main switch OFF --> foam marker OFF
Whenever the foam marker is ON, the active side automatically changes.
10.12
Pump Protector
Fig. 65
In this menu indicate if the Pump Protector is installed on the system
.
The “Pump Protector” sensor
(Code 4664000.100)
when connected to the computer, detects and
signals breakage of the pump diaphragm or indicates when the oil drops below its minimum level.