45
13.7
Output rate regulation
Bravo 300S regulates the chemical products output in two different ways.
Press the
AUTO
key to select the desired mode: the type of active regulation during the job will be displayed.
13.7.1 Automatic operation
(DEFAULT)
Fig. 121
Bravo 300S keeps the set spray rate constant regardless of the
changes in speed and boom section status.
If necessary, during the spraying, it is
possible to use the relevant switch
to adapt the output to the
crop conditions, temporarily increasing or reducing the application rate
up to ±50%.
1
Enable the automatic operation.
2
Open the desired section valves.
3
Position the tractor at the beginning of the field to be sprayed.
4
Turn the main switch to ON.
5
Start the treatment.
6
Use the control valve switch to temporarily change the
application rate.
Par. 13.2 Control, selection or modification keys
Par.13.3 Operating switches for control unit valves
Par.13.4 Operating switches for hydraulic valves
Par.13.5 Display
13.7.2 Manual operation
Fig. 122
Rate manual regulation shall be carried out with the suitable switch
1
Enable the manual operation.
2
Open the desired section valves.
3
Position the tractor at the beginning of the field to be sprayed.
4
Turn the main switch to ON.
5
Start the treatment.
6
Use the control valve switch to adjust the desired quantity.
Par. 13.2 Control, selection or modification keys
Par. 13.3 Operating switches for control unit valves
Par. 13.4 Operating switches for hydraulic valves
Par. 13.5 Display
13.8
Section valves automatic switch-off (through SKIPPER)
BRAVO 300S can automatically switch-off section and master valves through SKIPPER: the navigator can autonomously manage valve opening and
closing, thus preventing the overlapping of already-treated areas.
Connect SKIPPER to BRAVO 300S and carry out the AUTOMATIC operation procedure (Par. 13.7.1): for further information,
refer to the user's manual supplied with the SKIPPER satellite navigator.
WARNING: automatic closing is NOT active during manual operation.