49
• User setting
Data
description
min.
max.
uom
notes
Speed
Source
--
--
--
Values that can be set: Wheel sensor, GPS.
Selected wheel type
--
--
--
Possibility to save up to three types of wheel
Wheels setting
--
--
--
Groups sub-menus: Constant calculation, Wheel constant
Constant calculation
--
--
--
Value that can be set: Manual, Automatic
Wheel constant
0.01
150
Metric - L/100 m: cm/pls
Number of constant to be set: 1 ÷ 3
US: in/pls
Counting distance
20
1000
Metric - L/100 m: m
Distance to be traveled during automatic calculation of the
constant
60
3000
US: feet
Jobs setup
Select a job that can be set
1
19
--
--
Rate type
--
--
--
Values that can be set: Constant, Variable, Disabled
Target rate
Disab.
9999
Metric: l/ha
--
L/100 m: lhm
Disab.
999.9
US: GPA
Row width
0.00
99.99
Metric - L/100 m: m
Distance between rows
US: feet
Boom type
A
J
--
Values that can be set: Type A ÷ J
Nozzles setup
Flowrate
0.01
99.99
Metric - L/100 m: l/min
Value that can modified ONLY for customized nozzles
0.001
9.999
US: GPM
Pressure
0.1
99.9
Metric - L/100 m: bar
1
999
US: PSI
Minimum pressure alarm
Disab.
99.9
Metric - L/100 m: bar
--
Disab.
999
US: PSI
--
Maximum pressure alarm
Disab.
99.9
Metric - L/100 m: bar
--
Disab.
999
US: PSI
--
Boom setup
Nozzle number
0
99
--
--
Nozzle type
--
--
--
ATR (Par. 11.4 Booms setup)
Working limits
Nozzles wear check
Disab.
50
%
--
Min. spraying speed
Disab.
999.9
Metric - L/100 m: km/h
--
US: MPH
Regulation lock type
--
--
--
Groups the options:
Disabled, Min. regulation speed, Min. regulation pressure
Min. regulation speed
0.1
999.9
Metric - L/100 m: km/h
--
US: MPH
Min. regulation pressure
0.1
99.9
Metric - L/100 m: bar
--
1
999
US: PSI
Flowrate correct. factor
0.01
10.0
--
--
Test
Speed simulation
--
--
--
Values that can be set: No, Yes
• Totalizers: Job's data
Data
min.
max.
uom
Job No.
1
19
--
Covered area
0
999999
Metric - L/100 m: ha
US: ac
Sprayed quantity
0
9999999
Metric - L/100m: l
US: gal
Application time
0
99999
h
Productivity
0
99999.9
Metric - L/100 m: ha/h
US: ac/h
Rate sprayed
0
9999998
Metric: l/ha
L/100 m: lhm
US: gal/ac
Row width
0
99.99
Metric - L/100 m: m
US: ft
Nozzle number
0
999
-
Distance traveled
0
999999
Metric - L/100 m: km
US: miles
Worked rows
0
999999
Metric - L/100 m: km
US: miles
15.1
Computer technical data
Description
Display
Graphic LCD, 240 x 73 pixels, white back-lighting
Power supply
11 ÷ 14 Vdc
Consumption (valves excluded)
450 mA
Working temperature
0 °C ÷ 60 °C
+32 °F ÷ +140 °F
Digital inputs
for open collector sensors: max 2000 imp/s
Analog input
4 ÷ 20 mA
Weight
1108 g (Bravo with direct connection without harness)
1376 g (Bravo with RCU without harness)
Protection against polarity inversion
•
Protection against short-circuit
•
TECHNICAL DATA
*
pls = pulse
turn = turn