27
ADVANCED SETUP
10.13
Configuration check after Advanced setup end
This screen is displayed only in case of errors upon
Advanced setup
end:
Select
one error
Fig. 66
In case of more error messages, select the message and press
OK
.
Bravo 300S automatically passes to the
Advanced setup
and directly positions
on the value to be modified.
Below, the display shows the mismatching data.
par.
error message
set vaLues
Par. 8.5
Par. 10.9.2
Par. 10.10
Par. 10.12
> Disable an aux sensor
Two or more activated sensors that occupy the same harness input.
Tank level/
Mode/
Filling flowmeter:
> Orion 462...
or
> Other...
Rev counter:
> ..pls/turn
Pump Protector:
> Enabled
Par. 10.7
Par. 10.5
> Enable flowmeter
The setting for the rate calculation requires
the flowmeter, which is disabled though.
Delivery cal. sensor:
> Flowmeter
or
> Either
Flowmeter:
> Disabled
Par. 10.7
Par. 10.6
> Enable pressure sensor
The setting for the rate calculation requires
the pressure sensor, which is disabled though.
Delivery cal. sensor:
> Pressure
or
> Either
Pressure sensor:
> Disabled
Par. 10.8
> Enable automatic switch-off (M mode)
The control unit does not have a main valve:
the operation of “M” is compulsory.
Valves /
Automatic switch-off:
> No (P mode)
Valves /
Master:
> None
+
+
+
+
+
Par.9.3
Quick reset of
change
Menu item scrolling or
Data increase/decrease
Confirms access to menu
or data change
Quits the menu or
data changes