ADVANCED SETUP
10.9
Tank level
Select
one mode
Fig. 50
Fig. 51
First of all configure the submenu
Mode
and the selected option data.
The tank filling management, described in Par. 12.5 F4 - Tank (PAGE 1) will be different according to the selected mode.
Possible options:
> Manual
: Par. 10.9.1
> Filling flowmeter
: Par. 10.9.2
> Level sensor
: Par. 10.9.3
10.9.1 Tank level - Manual Mode
Fig. 52
> Capacity
: indicate the tank capacity.
> Minimum level alarm
: indicate the range value.
The tank alarm activates when during the treatment the tank level falls below the set value (Par. 13.5 Display).
10.9.2 Tank level - Filling flowmeter mode
Fig. 53
The filling flowmeter installed in the system allows displaying the tank filling data in real time.
> Capacity
: indicate the tank capacity.
> Minimum level alarm
: indicate the range value.
> Type
: indicate the filling flowmeter installed and the relevant data.
Tab. B contains the values that will be automatically set by selecting the flowmeter code.
Nevertheless the constant can be modified.
> Constant
: indicate the constant of the installed filling flowmeter.
orion fLowmeters
TYPE
UNIT OF MEASUREMENT
METRIC - METR. l/100 m
UNIT OF MEASUREMENT
US
The default constant can be
modified.
Constant
(pls/l)
Min. rate
(l/min)
Max. rate
(l/min)
Constant
(pls/gal)
GPM min.
flowrate
GPM max. rate
462xxA4xxxx
300
10.0
200.0
1135
2.60
53.00
4622xA5xxxx
150
20.0
400.0
568
5.00
106.00
4622xA6xxxx
100
30.0
600.0
378
8.00
158.00
Other...
625
10.0
100.0
156
2.60
53.00
Tab. B