33
USER SETTING
11.8
Date and Time
This menu allows setting the computer clock.
Fig. 89
> Modification locking code
Allows locking the modification of date and time set on the computer to obtain real reports.
• how to use the Locking code
- Enter the number to enable the locking;
- Enter the same number if you want to disable the data modification locking.
> Date
> Time
Set the Bravo 300S date and time.
• how to set date and time
- Select the item
Date
or
Time
and press
Ok
to modify it;
then press the “arrow” keys to change the values and press
OK
to confirm.
Any time you press
OK
, the cursor automatically moves from one field to the other.
Once all working fields have been set, Bravo 300S automatically quits the menu.
11.9
Data logger
Set the
recording
frequency
Fig. 90
Allows enabling / disabling the job data saving on SD card.
Set a saving interval (1, 2, 5, 10 s) to enable data recorder.
If you connect a satellite receiver or the SKIPPER navigator, the
Data logger
(properly enabled) allows recording the geographic position of the machine any time during the
treatment.
data recording fiLe
File name structure:
Reference job
number
(01÷19)
Progressive
number
LOG
Fig. 91
When the data recorder is enabled, Bravo 300S saves a
“LOG”
file on the SD card where the job data will be
saved
*
. The recording is activated when the main control is ON, and is carried out at the frequency set in the
Data logger
menu.
Any time you select a job, a new
“LOG”
file will be saved and its name (Fig. 91) will bear a progressive number
according to the number of savings (i.e..: 00001
00002).
Data in the file can be displayed on Personal Computer with a text editor.
They consist of a header followed by data strings (see example below).
Heading data:
#01: Manufacturer
#02: Software version
#03: number of sections, coverage
#04: Description of data in the following strings
Header example:
#01:Arag s.r.l.
#02:V.2.0.0.B11,524
#03:5,100,100,100,100,100
#04:date,time,lat,lon,sprayed rate,applied rate,recovery efficiency,speed,flow,pressure,rpm,sprayed quantity,applied quantity,tank level,covered area,row width,boom
type,sections
Data string content:
24/11/11 = Date (DD:MM:YY)
14:13:47 = Time (HH:MM:SS)
0.00000000 = Latitude
0.00000000 = Longitude
1292 = Rate sprayed
0 = Rate applied
100 = Recovery efficiency
5.0 = Speed
128.5 = Rate
595.4 = Pressure
0 = Rev counter
3 = Sprayed quantity
0 = Applied quantity
1998 = Tank level
0.028 = covered area
3.00 = Row width
c = Boom type
11011 = Section status (1 open, 0 closed: in the example all sections are open but the third one)
Example of data string:
24/11/11,14:13:47, 0.00000000, 0.00000000,1292,0,100,5.0,128.5,595.4,0,3,0,1998,0.028,3.00,c,11011
*
These data represent just a mere example. In real facts they will always be different according to the type of treatment.
Par.9.3
Quick reset of
change
Menu item scrolling or
Data increase/decrease
Confirms access to menu
or data change
Quits the menu or