9
The computer must be directly connected to the farming machine battery.
* Do not connect the computer to key-operated switch (15/54).
rcu
assembLy diagram for muLti-row sprayer with diaphragm pump - system with drain vaLve
Fig. 7
Legend:
a
Monitor
b
Battery
D
Filling pump
E
Hydraulic unit
f
Flowmeter
G
Drain valve
L
Level sensor
m
Pressure sensor
p
Control valve
r
Foam marker
s
Speed sensor
t
Filling flowmeter /
Pump Protector
u
RCU
X
RPM sensor
1÷5
Section valves
rcu
assembLy diagram for muLti-row sprayer with centrifugaL pump
Fig. 8
Legend:
a
Monitor
b
Battery
D
Filling pump
E
Hydraulic unit
f
Flowmeter
L
Level sensor
m
Pressure sensor
p
Control valve
r
Foam marker
s
Speed sensor
t
Filling flowmeter
u
RCU
X
RPM sensor
1÷5
Section valves
INSTALLATION