Page
87
Write Commands
Command Protocol
WSPT
Store setpoints
Store comparison parameters
64
characters.
This command stores setpoints of a selected code.
Parameters are 7 figures with "-" sign at MSB when negative
value and without decimal point.
Code number, Target, Hi, Lo, HiHi, LoLo,
Zero Band, Full, Code number
WCOD
Store code data without
total
96
characters.
This command stores all data of a selected code. Parameters
are 7 figures with "-" sign at MSB when negative value and
without decimal point. If code number is replaced with space
codes (20h), data is stored into the current code.
Code
number
WCOD0034,123456...,1234567
C
R
L
F
WCOD0034
Computer
AD-4404
C
R
L
F
Output item order
Length
Code number
RCOD + 4
Code name
12 + 3 spaces
Target 7
Hi 7
Lo 7
HiHi 7
LoLo 7
Zero band
7
Full 7
Preset tare
7
Target count
7
WSPT0034,1234567,1234567,1234567,1234567,1234567,
WSPT0034
Computer
AD-4404
1234567,1234567
C
R
L
F
C
R
L
F