6.5.
6.5.
6.5.
6.5.
Manual Mode
Manual Mode
Manual Mode
Manual Mode
The
manual mode
is the mode that weighs the article by hand operation and does
not use a conveyor.
In the stop mode, the current weighing value and comparison display are always updated.
The comparison output and buzzer are turned off. The comparison display is turned off,
when the weighing value is within zero band.
In the operation mode, the current weighing value is updated.
The detection of the article uses the weighing value that crosses from the zero band
and
Detector
[
5q f-29
] is not used.
The weighing procedure is as follows:
1 The comparison display, comparison output and buzzer are turned off, when the
weighing value is within the zero band.
2 When the article is weighed, the weighing display blinks once.
3
Eval delay timer
[
5q f-43
] and
Average timer
[
5q f-44
] are up.
4 The weight is judged.
5 The comparison result is output and the preset buzzer sounds.
6 The weighing value and the comparison display are held.
7 When the article is removed and the weighing value is within the zero band, the
hold display is canceled, comparison output and buzzer are canceled.
Concerning Principal Items
(Including Parameter Example)
Address
Parameter
Address name
Parameter name
Description
5q f-01
4
Weighing mode
Manual mode
5q f-02
1
Selection of comparison
3 levels with target
Setpoints and comparison method
Target, Lo (light), Hi(heavy)
5q f- 6
01000000
Buzzer condition 2
Buzzer sounds at Lo. Interval is 0.5Hz.
1: buzzer sounds, 0: no buzzer
5q f- 8
00100000
Buzzer condition 4
Buzzer sounds without OK. Interval is 2Hz.
1: buzzer sounds, 0: no buzzer
5q f-10
00010000
Buzzer condition 6
Buzzer sounds at Hi. Interval is 8Hz.
1: buzzer sounds, 0: no buzzer
5q f-41
500
Buzzer ON timer
Range is 0.00 to 99.99 sec.
5.00 seconds
Press the
START
key
and place the article.
AD-4404
The result can be indicated
Loadcell
OK