Page
126
AD-4404
11.2.
11.2.
11.2.
11.2.
Referring
Referring
Referring
Referring Parameters
Parameters
Parameters
Parameters
Use this mode to refer to the parameters in the weighing sequence.
The temporary parameters can be input and used concerning the digital filter and
weighing sequence timers in the weighing sequence.
[
genf- 2
]
Digital filtering
[Function] - [Function setting] - [General] - [Weighing]
[
genf- 3
]
Sampling frequency divisor
[Function] - [Function setting] - [General] - [Weighing]
[
5q f-31
] to [
5q f-48
]
Weighing sequence timers
[Function] - [Function setting] - [Sequence] - [Timer]
The temporary parameters can be reset by the following operation.
When entering into standby mode.
When entering into calibration mode.
When entering into function setting of the menu.
Operation Example
Step 1 Press and hold the
ENTER
key and press the key to display the menu.
Step 2 Select
Function
using the key and press the
ENTER
key.
Step 3 Enter
Refer function
using the
ENTER
key.
Step 4 Refer paremeters or input temporary parameters.
Step 5 Press the
ESC
key to return to the weighing mode several times.
Operation Example to Store Temporary Parameters
Step 1 Press and hold the
ENTER
key and press the key to display the menu.
Step 2 Select
Function
using the key and press the
ENTER
key.
Step 3 Enter
Refer function
using the
ENTER
key.
Step 4 Input temporary parameters.
Step 5 Press the
ESC
key and enter into
Set function
using the and
ENTER
key.
Then the weighing mode stops and parameters are stored.
Step 6 Press the
ESC
key to return the normal stop mode.