![AND Check Weighing Indicator AD-4404 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/and/check-weighing-indicator-ad-4404/check-weighing-indicator-ad-4404_instruction-manual_2941313022.webp)
Page
20
4.2.2.
4.2.2.
4.2.2.
4.2.2.
Status of Weighing Mode
Status of Weighing Mode
Status of Weighing Mode
Status of Weighing Mode
Weighing mode comprises of the following modes.
Operation mode
includes the following check weighing (weighing sequence).
Automatic
mode
Conveyor
stop
mode
OK
mode
Manual
mode
Simple
mode
The
normal
stop mode
displays the current weighing value.
Use this mode generally to enter parameters of the function list into the indicator.
The
emergency stop mode
assumes that the preset input terminal is connected to
the emergency stop key.
The
"
Input
" means key operation, command from peripheral equipment or signal
level of the preset input terminal.
Operation Mode
Check weighing sequence is working.
Stop Mode
Normal Stop Mode
A status error occurs, while not in a weighing sequence, this mode works.
When the indicator is turned on and an error occurs, this mode works.
When not a BUSY signal and a stop command is input, this mode works.
The stop input is entered.
The operation input is entered.
An error occurs
during operation.
A stop input is entered.
Pause
An error occurs during a weighing sequence, this mode works.
When a stop input is entered during BUSY, this mode works.
An emergency stop
signal is active.
Emergency stop
signal is inactive.
An emergency stop
signal is active.
Emergency Stop Mode
Current sequence is stopped.
Current sequence is stopped.
If an emergency stop signal is entered, this mode works.
This mode can not enter into the operation mode directly.
Содержание Check Weighing Indicator AD-4404
Страница 1: ...Check Weighing Indicator WM PD4000489...
Страница 28: ...Page 26 Blank page...