User Manual – Rev J
CS Series
California Instruments
72
ENTRY
DESCRIPTION
shown as six hexadecimal numbers separated
by a colon, e.g. 00:20:4A:9A:02:FD. Note that
the leading ‘0’ is never visible due to the
maximum number of LCD characters per line.
Note: If the MAC Address displayed is
corrupted or does not match the serial tag,
there may have been a problem retrieving the
LAN port settings. This can happen if a static
IP was set that conflicts with another device
on the network. To recover, turn on power to
the unit while holding down the SET key. This
will allow the unit to boot without attempting to
collect the IP settings. You can then set the
required IP values. [See IP Address above].
GWAddress
Gateway address setting. A default gateway is
a node (a router) on a computer network that
serves as an access point to another network.
This value can be changed by pressing the
SET key and entering a new value from the
keypad or using the Voltage and Frequency
shuttles. Use the numeric data pad or the
Voltage shuttle to enter each field. To move
between the four fields, use the decimal point
key on the keypad or the Frequency shuttle.
Any change to this value will NOT take effect
until after power on the unit has been cycled.
HostBits
Number of host bits as opposed to network
bits in network mask. A CIDR class C network
uses 24 network bits and 8 host bits. (Class A
= 24, Class B = 16).
This value can be changed by pressing the
SET key and entering a new value from the
keypad. Any change to this value will NOT
take effect until after power on the unit has
been cycled.
Port No
TCP remote port number. This value must be
set to 5025 (SCPI) to support the built in web
page.
This value can be changed by pressing the
SET key and entering a new value from the
keypad. Any change to this value will NOT
take effect until after power on the unit has
been cycled.
LAN Default
LAN default setting can be achieve by
selecting the Mac address screen and press
the set key followed by the Enter key. Press
the Enter key again to confirm. The IP
address is set to DHCP or AUTO IP.
Содержание 13500CS/3
Страница 5: ...User Manual Rev J CS Series California Instruments 5 SAFETY SYMBOLS ...
Страница 34: ...User Manual Rev J CS Series California Instruments 34 Figure 3 3 9000CS 2 Wiring diagram 3 Phase mode ...
Страница 35: ...User Manual Rev J CS Series California Instruments 35 Figure 3 4 13500CS 3 Wiring diagram 3 Phase mode ...
Страница 36: ...User Manual Rev J CS Series California Instruments 36 Figure 3 5 18000CS 4 Wiring diagram 3 Phase mode ...
Страница 56: ...User Manual Rev J CS Series California Instruments 56 The power source is now ready to be used ...
Страница 73: ...User Manual Rev J CS Series California Instruments 73 ...
Страница 111: ...User Manual Rev J CS Series CS Series 111 voltage rating 28 W Weight 22 Wiring AC input 30 ...