User Manual – Rev J
CS Series
California Instruments
28
2.6.5
–LNS Option CS Series - Supplemental Specifications
The –LNS(AC Line Sync) option allows the output frequency of the AC source to be synchronized to the AC
line frequency used to feed the power source.
The following supplemental specifications apply when the CS is configured with the AC line sync option. (-
LNS).
Parameter
Supplemental Specification
Input
AC Line Synced to Phase B-C (line to line) AC input.
Frequency
Range Same as allowable AC input frequency range.
Max Sync Input Slew Rate < 80 Hz / sec.
Changes in sync input frequency occurring faster than this rate will result in
Error 804: External Sync Error. Output relay is opened on Error.
Max Sync Step < 20 Hz.
Sudden changes in sync input frequency greater than 20 Hz will result in
Error 804: External Sync Error. Output relay is opened on Error.
Mode Selection
When switching between INT and LINE sync mode, the output of the AC
source will be dropped momentarily.
Restrictions
Frequency cannot be programmed in line sync mode.
Frequency transient list system is not available in line sync mode.
Transient list dwell times are not correlated to line sync but based on
internal timebase.
Содержание 13500CS/3
Страница 5: ...User Manual Rev J CS Series California Instruments 5 SAFETY SYMBOLS ...
Страница 34: ...User Manual Rev J CS Series California Instruments 34 Figure 3 3 9000CS 2 Wiring diagram 3 Phase mode ...
Страница 35: ...User Manual Rev J CS Series California Instruments 35 Figure 3 4 13500CS 3 Wiring diagram 3 Phase mode ...
Страница 36: ...User Manual Rev J CS Series California Instruments 36 Figure 3 5 18000CS 4 Wiring diagram 3 Phase mode ...
Страница 56: ...User Manual Rev J CS Series California Instruments 56 The power source is now ready to be used ...
Страница 73: ...User Manual Rev J CS Series California Instruments 73 ...
Страница 111: ...User Manual Rev J CS Series CS Series 111 voltage rating 28 W Weight 22 Wiring AC input 30 ...