User Manual – Rev J
CS Series
California Instruments
23
Parameter
Specification
Altitude:
< 2000 meters
< 6000 feet
Relative Humidity:
0-95 % RAH, non-condensing maximum for temperatures up to 31
°
C
decreasing linearly to 50% at 40
°
C.
Indoor Use Only
Vibration:
Designed to meet NSTA project 1A transportation levels.
Shock:
Designed to meet NSTA project 1A transportation levels.
2.4
Front Panel Controls
Controls:
Shuttle knob:
The shuttle knob may be used to adjust current and frequency for
selected phase or all three phases while in the SET menu. In all other
menus, the shuttle may be used to change parameter values and
settings.
Up/down arrow keys:
A set of up and down arrow keys is used to move the cursor position in
all menus. This allows quick selection of the desired function or
parameter.
Function keys:
Set
key will show output voltage and frequency setting.
Meas
key displays the measurement screens. Measure key will display
measurement values for selected phase or phase A if all three phases
are selected.
Menu
key selects main menu.
Enter
key is used to confirm selections.
Back
key is used to back up to previous screen.
Output on/off
key for output relay control.
Phase
key toggles between phase A, B, C or all phases selection.
Keypad
is used to enter numeric values without using the shuttle knob.
Displays:
LCD graphics display:
Large high contrast backlit LCD display. An adjustable viewing angle
makes it easy to read from all practical locations.
Status indicators:
Large and bright status indicators inform the user of important power
source conditions.
The Remote lamp informs the user that the unit is under remote control.
The Overvoltage lamp indicates that excessive compliance voltage is
present at the output.
The Over temperature lamp illuminates when internal heat sink
temperatures are too high.
The Hi Range indicator is lit any time the unit is switched to the high
current range.
The Output On/Off indicator is on when the power source output relays
are closed.
The Phase A, B and C indicators are lit when the relevant phase is
selected with the Phase key.
Содержание 13500CS/3
Страница 5: ...User Manual Rev J CS Series California Instruments 5 SAFETY SYMBOLS ...
Страница 34: ...User Manual Rev J CS Series California Instruments 34 Figure 3 3 9000CS 2 Wiring diagram 3 Phase mode ...
Страница 35: ...User Manual Rev J CS Series California Instruments 35 Figure 3 4 13500CS 3 Wiring diagram 3 Phase mode ...
Страница 36: ...User Manual Rev J CS Series California Instruments 36 Figure 3 5 18000CS 4 Wiring diagram 3 Phase mode ...
Страница 56: ...User Manual Rev J CS Series California Instruments 56 The power source is now ready to be used ...
Страница 73: ...User Manual Rev J CS Series California Instruments 73 ...
Страница 111: ...User Manual Rev J CS Series CS Series 111 voltage rating 28 W Weight 22 Wiring AC input 30 ...