162
Version 1.00
SYSTEM SETUP
RECORD SETUP
Pressing RECORD (F3) on the SINGLE MACHINE SETUP page will take you to the following
page:
This page is very similar to the RECORD SETUP page described earlier in the section on recording
and includes all the same parameters. Additionally, it provides direct access to the ROUTE INPUTS
page for the selected machine.
OPERATING LEVELS
The DD8 includes a software controlled adjustment for the operating levels of its A/D and D/A
convertors. When a DD8 is selected, pressing LEVELS (F4) on the SINGLE MACHINE SETUP
page will take you to the following page:
The parameters on this page are:
MACHINE
This allows you to select which machine in the system you are configuring.
REFERENCE LEVEL
The Reference Level is used to set the 0 VU of the A/D and D/A
converters.
Available selections are -12 dB , -16 dB, -18 dB and -20 dB.
If a machine that does not have support for this function is selected, you will see the following
message:
Содержание RE32
Страница 10: ...Page ix ...