142
Version 1.00
SYSTEM SETUP
SETUP - MULTI
When MULTI mode is selected, pressing the SETUP key will display the following options:
The MULTI SETUP pages are designed to allow easy configuration of parameters that should be
set identically on each machine connected to the system.
Pressing RATES (F1) will take you to the SYSTEM RATES page:
This page is used to set the system’s global sample rate and frame rate.
The parameters are:
SAMPLE RATE
This sets the system’s sample rate. You may select 32kHz, 44.056kHz,
44.1kHz and 48kHz. Other options may be available depending on the
facilities available on the connected machines.
On entry to this page, if all connected machines are set to the same
sample rate, then this rate will be displayed. If not, the sample rate field
will say “* DO NOT MATCH *” until a new rate is selected.
NOTE 1: This page will only allow selection of sample rates that are supported on all the
connected machines.
NOTE 2: Recordings made at a sample rate other than the selected sample rate will play back
at the wrong speed. For example, if the sample rate is set to 44.1kHz and you try to play back
a recording made at 48kHz, the recording will play back slow. Therefore, please make sure
that your recordings are made at the correct sampling rate. Recordings made at different
sample rates cannot be used in the same project.
TC FRAME RATE
This shows the system’s timecode rate.
This field is not editable, but instead serves as a visual check that all
machines are configured correctly. If all machines are set to the same
frame rate, then this rate will be displayed here. If not, this field will say
“* DO NOT MATCH *”.
Timecode frame rates can be individually set on each machine as
explained later in the section on TIMECODE SETUP.
Содержание RE32
Страница 10: ...Page ix ...