Auto Width Adjust Conveyor Setup
6
Agilent U1840A Medalist sj5000 Hardware Manual
6-7
AWA Setup and Calibration
Perform the following steps:
1
Set up the sensors and flags. Refer to
for instructions. Also see
for a
description of the sensors and flags.
2
Ensure that all sensors and I/O are working correctly:
Trigger each of the AWA sensors individually, using a small
screwdriver or piece of paper to simulate the sensor
triggering. You will need another person check the PLC
inputs on the control panel in the rear of the machine. Verify
that the PLC input LED turns on and off as you activate and
deactivate the sensor.
Auto Width Adjust Calibration
1
Ensure there are no boards in the sj5000.
2
Launch the sj5000 software in Engineer mode.
3
From the
Tools
menu click the
Auto Width Adjust
folder.
4
Click
Calibrate
.
5
Open the front access door. Adjust the rails inwards until
they can no longer move. (The ball screw housing rubber
stops will not allow further movement.)
Input
Sensor
01.00
Left Max Sensor
01.01
Left Min Sensor
01.02
Right Min Sensor
Содержание U1840A Medalist sj5000
Страница 15: ...Safety and Regulatory Information 1 Agilent U1840A Medalist sj5000 Hardware Manual 1 9...
Страница 50: ...3 12 Agilent U1840A Medalist sj5000 Hardware Manual 3 Installation...
Страница 100: ...7 18 Agilent U1840A Medalist sj5000 Hardware Manual 7 Camera and Lighting Calibration...
Страница 134: ...10 18 Agilent U1840A Medalist sj5000 Hardware Manual 10 Setting Up Barcode Readers...
Страница 176: ...11 42 Agilent U1840A Medalist sj5000 Hardware Manual 11 Troubleshooting...
Страница 181: ...Maintenance 12 Agilent U1840A Medalist sj5000 Hardware Manual 12 5 Figure 12 2 Sensors on the conveyor...
Страница 190: ...A 4 Agilent U1840A Medalist sj5000 Hardware Manual A System Specifications...
Страница 192: ...B 2 Agilent U1840A Medalist sj5000 Hardware Manual B Reference Documents...