Auto Width Adjust Conveyor Setup
AWA Mechanical Setup
To achieve accuracy when the conveyor homes and moves to its
desired width, check the position of the maximum and
minimum sensors and set them up according to the factory
default.
shows the sensor distances to be set. Use a steel ruler
to measure from the base to the sensor edge. If the
measurements are different from those shown, loosen the
sensor setting screw, adjust the sensor position, and tighten the
screw to secure the sensor.
Figure 6-1
Sensor positions
155 mm
72 mm
Max Sensor
Min Sensor
155 mm