Safety and Regulatory Information
1
Agilent U1840A Medalist sj5000 Hardware Manual
1-7
The Emergency stop circuit has the following attributes
associated with it:
•
During an E-Stop, power is removed from all motors
including conveyors and XY Table. The only exception is that
turning the maintenance key switch to the “on” position
re-enables power to the clamping motors. This allows the
clamping motors to be operated for engineering tests,
troubleshooting or calibration.
•
E-Stop overrides all modes of operation within the SJ5000
machine.
•
When power is removed from the system, the E-Stop is
activated automatically and must be reset on powering the
machine back up.
There are two ways to reset the E-stop. If the system
software is running, click
Okay
to remove the E-stop
condition. If the system software is not running, press the
blue ES RESET button on the switch plate. In either case, you
must first fix the condition that caused the E-stop by either
closing the front door or pulling the E-stop button out.
Front Switch Panel - sj5000
•
On startup, NO uncontrolled motion can occur.
Содержание U1840A Medalist sj5000
Страница 15: ...Safety and Regulatory Information 1 Agilent U1840A Medalist sj5000 Hardware Manual 1 9...
Страница 50: ...3 12 Agilent U1840A Medalist sj5000 Hardware Manual 3 Installation...
Страница 100: ...7 18 Agilent U1840A Medalist sj5000 Hardware Manual 7 Camera and Lighting Calibration...
Страница 134: ...10 18 Agilent U1840A Medalist sj5000 Hardware Manual 10 Setting Up Barcode Readers...
Страница 176: ...11 42 Agilent U1840A Medalist sj5000 Hardware Manual 11 Troubleshooting...
Страница 181: ...Maintenance 12 Agilent U1840A Medalist sj5000 Hardware Manual 12 5 Figure 12 2 Sensors on the conveyor...
Страница 190: ...A 4 Agilent U1840A Medalist sj5000 Hardware Manual A System Specifications...
Страница 192: ...B 2 Agilent U1840A Medalist sj5000 Hardware Manual B Reference Documents...