11-36
Agilent U1840A Medalist sj5000 Hardware Manual
11
Troubleshooting
8
Do the same for Axis 1. To have the axis move back and
forward continuously, select the
Enabled
option for
Repeat
Mode
and than click
Move to Further
.
9
If the axes are moving, it means the system is ready for
inspection. Disable the Repeat Mode, disable the motors
(disable
Amp Enable
in the Motor Summary window), and
close the MoCon window.
Mapping the Axes
1
On the MoCon toolbar, click the Object Controller button (to
the left of the C button).
2
Open the
Controller 0
folder, then the
Motion Supervisors
and
Axes
subfolders.