Maintenance
12
Agilent U1840A Medalist sj5000 Hardware Manual
12-3
Weekly Maintenance
Carry out the following maintenance procedure weekly:
•
Run a board through the sj5000 and ensure that it is
operating correctly.
•
Clean the machine panels.
•
Clean the PC filter, if fitted.
•
Check that all fans are running.
•
Check that the control panel fan is running.
•
Inspect the XY table and check all cables and connectors.
•
Move the XY table by hand. Ensure that it moves freely and is
not obstructed throughout its full range of movement on both
X and Y axes.
•
Test the E-Stop circuit by opening and closing the front
access door. Reset the E-Stop circuit using the
ES Reset
button at the front of the sj5000.
•
Test the E-Stop circuit by pressing an E-Stop button. Reset
the E-Stop circuit by pulling out the E-Stop button and
pressing the
ES Reset
button.
•
Repeat this procedure for each of the other E-Stop buttons.
•
Start the AWA software and home the AWA conveyor. Move it
to a width of 100 mm and measure both sides of the conveyor
to ensure that the calibration is good.
•
Power down the machine and switch off the XY stage at the
controller.
Figure 12-1
XY gantry
Содержание U1840A Medalist sj5000
Страница 15: ...Safety and Regulatory Information 1 Agilent U1840A Medalist sj5000 Hardware Manual 1 9...
Страница 50: ...3 12 Agilent U1840A Medalist sj5000 Hardware Manual 3 Installation...
Страница 100: ...7 18 Agilent U1840A Medalist sj5000 Hardware Manual 7 Camera and Lighting Calibration...
Страница 134: ...10 18 Agilent U1840A Medalist sj5000 Hardware Manual 10 Setting Up Barcode Readers...
Страница 176: ...11 42 Agilent U1840A Medalist sj5000 Hardware Manual 11 Troubleshooting...
Страница 181: ...Maintenance 12 Agilent U1840A Medalist sj5000 Hardware Manual 12 5 Figure 12 2 Sensors on the conveyor...
Страница 190: ...A 4 Agilent U1840A Medalist sj5000 Hardware Manual A System Specifications...
Страница 192: ...B 2 Agilent U1840A Medalist sj5000 Hardware Manual B Reference Documents...