11-12
Agilent U1840A Medalist sj5000 Hardware Manual
11
Troubleshooting
Troubleshooting the Camera
•
Camera image is completely black
•
•
•
Lighting controller will not work
•
Images seem darker than normal
•
Wrong lighting values or incorrect color in lighting menu
•
Camera image is completely black
•
Verify that the cap is not on the camera lens. Typically
systems are shipped with the cap on the camera lens.
•
Check that the cables (part numbers 5186-5778 and
5186-6325) are connected from the camera to the Frame
Grabber.
•
Check for 12 V DC on pins 4 and 16 on the cable (p/n
5186-6324) connected to the lighting controller.
Camera will not work
•
Check that the PC is on.
•
Check that the cable (p/n 5186-6325) and the two camera
link cables on the camera are connected correctly to the
Frame Grabber. Data1 and data2 on the camera should be
connected to the upper and lower connector of the Frame
Grabber respectively.
•
Check that the green LED of the camera is on when the PC is
on.
•
Check for 12 V DC between pins 4 and 16 on the cable (p/n
5186-6324) connected to the lighting controller.
Содержание U1840A Medalist sj5000
Страница 15: ...Safety and Regulatory Information 1 Agilent U1840A Medalist sj5000 Hardware Manual 1 9...
Страница 50: ...3 12 Agilent U1840A Medalist sj5000 Hardware Manual 3 Installation...
Страница 100: ...7 18 Agilent U1840A Medalist sj5000 Hardware Manual 7 Camera and Lighting Calibration...
Страница 134: ...10 18 Agilent U1840A Medalist sj5000 Hardware Manual 10 Setting Up Barcode Readers...
Страница 176: ...11 42 Agilent U1840A Medalist sj5000 Hardware Manual 11 Troubleshooting...
Страница 181: ...Maintenance 12 Agilent U1840A Medalist sj5000 Hardware Manual 12 5 Figure 12 2 Sensors on the conveyor...
Страница 190: ...A 4 Agilent U1840A Medalist sj5000 Hardware Manual A System Specifications...
Страница 192: ...B 2 Agilent U1840A Medalist sj5000 Hardware Manual B Reference Documents...