The supplementary equipment grounding conductor shall not be smaller in
size than the ungrounded branch-circuit supply conductors. The supple-
mentary equipment grounding conductor shall be connected to the product
at the terminal provided, and shall be connected to ground in a manner that
will retain the ground connection when the product is unplugged from the
receptacle. The connection to ground of the supplementary equipment
grounding conductor shall be in compliance with the rules for terminating
bonding jumpers at Part K or Article 250 of the National Electrical Code,
ANSI/NFPA 70. Termination of the supplementary equipment grounding
conductor is permitted to be made to building steel, to a metal electrical race-
way system, or to any grounded item that is permanently and reliably con-
nected to the electrical service equipment ground.
REVIEW THE REAR PANEL DESIGN
The ATLAS 800
PLUS
rear panel contains eight slots for housing option mod-
ules which provide a variety of additional resources and data ports. All slots
are functionally identical, except slots 7 and 8. These slots can also accom-
modate an optional power supply for redundancy Figure 2-1 (AC powered
unit) and Figure 2-2 (DC powered unit).
Figure 2-1. AC Powered ATLAS 800
PLUS
Rear Panel
4A/25OV SLOBLO
I
O
CONTROL
/CHAIN
IN
OUT
MON
10 BASE T
NTWK 1 NTWK 2
CAUTION:
CAUTION: FOR CONTINUED PROTECTION
AGAINST RISK OF FIRE REPLACE ONLY
WITH SAME TYPE AND RATING OF FUSE.
1
2
3
4
5
6
7
8
90-130/190-240VAC
4A/2A, 50/60 HZ
CAUTION: MAINTENANCE TO BE PERFORMED BY TRAINED SERVICE PERSONNEL ONLY
REMOVE POWER CORD PRIOR TO
ALL EMPTY SLOTS MUST BE COVERED WITH BLANK PANELS
CAUTION-RISK OF
ELECTRIC SHOCK
SUPPLAMENTAL EARTH GROUND MUST BE CONNECTED
PRIOR TO CONNECTION OF TELECOMMUNICATION WIRING
REMOVAL OF POWER SUPPLY
Power Switch
Blank panel covering an
unused option slot
Control/
Chain In
Interface of
Chain In
Control/Chain Out
Connects to Chain
In of another unit
10 Base T
RJ-48C Connec-
tion Port
MON (Monitor)
Bantam test jack
NTWK1
RJ-48C Connec-
tion Port
NTWK2
RJ-48C Connection
Port
Supplemental
earth ground lug
Содержание Atlas 800 Plus
Страница 1: ...ATLAS 800PLUS User Manual Part Number 1200226L1 Part Number 1200228L1 61200226L1 1C May 2000...
Страница 12: ...xii...
Страница 26: ...List of Tables xxvi ATLAS 800PLUS User Manual 61200226L1 1...
Страница 34: ...Chapter 1 Introducing the ATLAS 800PLUS 1 8 ATLAS 800PLUS User Manual 61200226L1 1...
Страница 48: ...Chapter 3 Operating the ATLAS 800PLUS 3 6 ATLAS 800PLUS User Manual 61200226L1 1...
Страница 66: ...Chapter 5 Navigating the Terminal Menu 5 6 ATLAS 800PLUS User Manual 61200226L1 1...
Страница 94: ...Chapter 7 Modules Terminal Menu 7 8 ATLAS 800PLUS User Manual 61200226L1 1...
Страница 104: ...Chapter 8 Dedicated Maps Terminal Menu 8 10 ATLAS 800PLUS User Manual 61200226L1 1 Figure 8 5 Completed Dedicated Map...
Страница 112: ...Chapter 9 Dedicated Circuit Backup and Circuit Status 9 8 ATLAS 800PLUS User Manual 61200226L1 1...
Страница 180: ...Appendix A System Event Logging A 14 ATLAS 800PLUS User Manual 61200226L1 1...
Страница 184: ...Appendix B Troubleshooting B 4 ATLAS 800PLUS User Manual 61200226L1 1...
Страница 208: ...Index Index 14 ATLAS 800PLUS User Manual 61200226L1 1...
Страница 210: ......