Chapter 12. SNMP Management
61200226L1-1
ATLAS 800
PLUS
User Manual
12-5
When one of the Current Alert thresholds is exceeded, the corresponding
event bit is set to 1 in the adDS1CurrentAlert variable in the DS1 alert table.
When enabled, ATLAS 800
PLUS
sends alert traps to each member of the trap
destination list upon detecting status bit changes in adDS1CurrentAlert. If
you have previously set the corresponding enable bit = 1 in the
adDS1CurrentArm variable and adDS1AlertEnable = On, then
ATLAS 800
PLUS
sends an alert trap message. A single alert trap message
may report multiple event changes. ATLAS 800
PLUS
clears the event bits af-
ter sending the trap message or sending the response to a Get request for the
adDS1CurrentAlert variable. ATLAS 800
PLUS
clears the Current Alert values
at the beginning of a new 15-minute interval. Total Alert values are cleared
at the beginning of a new 24-hour interval.
Table 12-5 shows the Total Alert Traps, which describe events that have oc-
curred in the last 24-hour interval.
adATLAS800CurrentUAS
Major
The current interval is unavailable.
adATLAS800CurrentCSS
Warning
The current interval path code violations have been
exceeded.
adATLAS800CurrentLES
Warning
The current interval line errored second threshold has
been exceeded.
adATLAS800CurrentCV
Warning
The current interval line code violation threshold has
been exceeded.
Table 12-4. DS1 Current Alert SNMP Traps (Continued)
Current Alert
Severity
Description
Table 12-5. Total Alert Traps
Total Alert
Severity
Description
adATLAS800TotalES
Warning
The total interval errored second threshold has been
exceeded.
adATLAS800TotalSES
Warning The total interval severely errored second threshold has
been exceeded.
adATLAS800TotalSEFS
Warning
The total interval severely errored framing second threshold
has been exceeded.
adATLAS800TotalUAS
Major
The total interval unavailable second threshold has been
exceeded.
adATLAS800TotalCSS
Warning
The total interval controlled slip second threshold has been
exceeded.
adATLAS800TotalPCV
Warning
The total interval path code violations has bee exceeded.
Содержание Atlas 800 Plus
Страница 1: ...ATLAS 800PLUS User Manual Part Number 1200226L1 Part Number 1200228L1 61200226L1 1C May 2000...
Страница 12: ...xii...
Страница 26: ...List of Tables xxvi ATLAS 800PLUS User Manual 61200226L1 1...
Страница 34: ...Chapter 1 Introducing the ATLAS 800PLUS 1 8 ATLAS 800PLUS User Manual 61200226L1 1...
Страница 48: ...Chapter 3 Operating the ATLAS 800PLUS 3 6 ATLAS 800PLUS User Manual 61200226L1 1...
Страница 66: ...Chapter 5 Navigating the Terminal Menu 5 6 ATLAS 800PLUS User Manual 61200226L1 1...
Страница 94: ...Chapter 7 Modules Terminal Menu 7 8 ATLAS 800PLUS User Manual 61200226L1 1...
Страница 104: ...Chapter 8 Dedicated Maps Terminal Menu 8 10 ATLAS 800PLUS User Manual 61200226L1 1 Figure 8 5 Completed Dedicated Map...
Страница 112: ...Chapter 9 Dedicated Circuit Backup and Circuit Status 9 8 ATLAS 800PLUS User Manual 61200226L1 1...
Страница 180: ...Appendix A System Event Logging A 14 ATLAS 800PLUS User Manual 61200226L1 1...
Страница 184: ...Appendix B Troubleshooting B 4 ATLAS 800PLUS User Manual 61200226L1 1...
Страница 208: ...Index Index 14 ATLAS 800PLUS User Manual 61200226L1 1...
Страница 210: ......