» Type
Write security:3; Read security:5
Displays the type of module actually installed in the slot or the type of
module you plan to install in the slot. The ATLAS 800
PLUS
automatically
detects the type of module installed in each slot, and the
Type
field automat-
ically defaults to the installed module type. You can also use this field to
pre-configure a unit before actually installing modules by specifying the
module that you want to install in each slot.
To use this option, navigate to the field you want to edit and press
Enter
. For
empty slots, a list of all the available module types displays. Select the one
you want and it displays in the
Type
field. If this field is already configured
with a module, you can only set this field to
Empty
.
» Menu
Displays additional status and configuration menus for the selected module.
To access the submenus for this item, use the
Arrow Keys
to scroll to the
Menu
column for the module you want to edit, and press
Enter
. For detailed infor-
mation on each submenu item, see Modules (Quad T1/PRI) Menu on page 7-3.
» Alarm
Read security:5
Displays whether there is an alarm condition on the ATLAS 800
PLUS
Base
Unit. Press
Enter
to access the
Alarm
menu.
» Test
Read security:5
Displays whether the ATLAS 800
PLUS
is executing a test. To initiate a test,
choose the
Menu
submenu on this screen. Then, select the
Test
option to
access the screen that allows you to set up and initiate tests. See Test on page
7-2 for details. Press
Enter
to access the
Test
menu.
» State
Read security:5
Displays whether the module is online of offline. Even though a module is
physically installed, it must be marked
Online
for it to be considered an
available resource. This parameter allows an installed module to be marked
Offline
, which may be useful in system troubleshooting. If you choose
Offline
, the module will not be in alarm condition, but will display
Offline
.
If you install a module in a slot, then want to install a different type of
module in the slot, you must set this field to
Empty
before selecting
another module type.
If a module is installed, the module type automatically shows the
name of the installed module, and it cannot be set to any other option.
Once a module is installed, you must change the state to Online in
order for the ATLAS to utilize the module for any data bandwidth.
Содержание Atlas 800 Plus
Страница 1: ...ATLAS 800PLUS User Manual Part Number 1200226L1 Part Number 1200228L1 61200226L1 1C May 2000...
Страница 12: ...xii...
Страница 26: ...List of Tables xxvi ATLAS 800PLUS User Manual 61200226L1 1...
Страница 34: ...Chapter 1 Introducing the ATLAS 800PLUS 1 8 ATLAS 800PLUS User Manual 61200226L1 1...
Страница 48: ...Chapter 3 Operating the ATLAS 800PLUS 3 6 ATLAS 800PLUS User Manual 61200226L1 1...
Страница 66: ...Chapter 5 Navigating the Terminal Menu 5 6 ATLAS 800PLUS User Manual 61200226L1 1...
Страница 94: ...Chapter 7 Modules Terminal Menu 7 8 ATLAS 800PLUS User Manual 61200226L1 1...
Страница 104: ...Chapter 8 Dedicated Maps Terminal Menu 8 10 ATLAS 800PLUS User Manual 61200226L1 1 Figure 8 5 Completed Dedicated Map...
Страница 112: ...Chapter 9 Dedicated Circuit Backup and Circuit Status 9 8 ATLAS 800PLUS User Manual 61200226L1 1...
Страница 180: ...Appendix A System Event Logging A 14 ATLAS 800PLUS User Manual 61200226L1 1...
Страница 184: ...Appendix B Troubleshooting B 4 ATLAS 800PLUS User Manual 61200226L1 1...
Страница 208: ...Index Index 14 ATLAS 800PLUS User Manual 61200226L1 1...
Страница 210: ......