Chapter 10. Dial Plan Terminal Menu
10-18
ATLAS 800
PLUS
User Manual
61200226L1-1
»» Ports Available
Indicates which of the four ports of the Quad Nx56/64 module have
already been defined either in another switched end point (indicated by
“s”) or in a Dedicated Map (indicated by “n”). This field is read-only.
»» Number of Ports
Defines to ATLAS how many of the ports could be used to answer calls to
the number(s) defined in the Accept Call list. You can enter numbers 1
through 4. The ports are contiguous beginning with the Port number select
and the number of ports.
For example, if the port selected (as a part of Slot/Port selection) is 2, and
the number of ports selected here was 2, then ports 2 and 3 would be
enabled to receive calls to the numbers listed under the Incoming Call
Accept list.
»» Number to dial
When originating a call, this is the number to dial.
»» Call Type
Specifies whether originated calls 56K or 64K.
»» Dial Call As
Specifies whether originated calls are dialed as Digital, Voice, or Audio.
»» Source ID
Source ID for the outgoing call.
»» Min DS0s
Minimum number of DS0s to connect with using BONDING. Note that this
requires the IMUX-56/64 module.
»» Max DS0s
Maximum number of DS0s to connect with using BONDING. Note that this
requires the IMUX-56/64 module.
OCTAL BRI MODULE (NETWORK TERMINATION)
The Octal BRI with a “U” interface can interface directly to the Network
(PSTN). When you are working in the
Network Termination
section of the
Dial Plan
menu and the
Slot
is defined as a UBRI-8 option module, the fol-
lowing interface configuration options are available:
»» Switch Type
Write security: 2; Read security: 5
Defines the type of ISDN switch that ATLAS is connected to. If connected to
another ATLAS, both need to be set to the same type. The available options
are Lucent 5E, Northern DMS 100, and National ISDN.
»» SPID List
Write security: 2; Read security: 5
In order to properly operate with a network (PSTN) ISDN switch, the BRI in-
terface must have SPID (Service Profile Identifier) and phone number(s) that
match the SPID(s) and Phone number(s) which have been programmed into
the ISDN switch for this line. Each BRI may have one or more phone num-
bers and SPIDs. The
SPID Number
list submenu defines to ATLAS these pa-
rameters.
Содержание Atlas 800 Plus
Страница 1: ...ATLAS 800PLUS User Manual Part Number 1200226L1 Part Number 1200228L1 61200226L1 1C May 2000...
Страница 12: ...xii...
Страница 26: ...List of Tables xxvi ATLAS 800PLUS User Manual 61200226L1 1...
Страница 34: ...Chapter 1 Introducing the ATLAS 800PLUS 1 8 ATLAS 800PLUS User Manual 61200226L1 1...
Страница 48: ...Chapter 3 Operating the ATLAS 800PLUS 3 6 ATLAS 800PLUS User Manual 61200226L1 1...
Страница 66: ...Chapter 5 Navigating the Terminal Menu 5 6 ATLAS 800PLUS User Manual 61200226L1 1...
Страница 94: ...Chapter 7 Modules Terminal Menu 7 8 ATLAS 800PLUS User Manual 61200226L1 1...
Страница 104: ...Chapter 8 Dedicated Maps Terminal Menu 8 10 ATLAS 800PLUS User Manual 61200226L1 1 Figure 8 5 Completed Dedicated Map...
Страница 112: ...Chapter 9 Dedicated Circuit Backup and Circuit Status 9 8 ATLAS 800PLUS User Manual 61200226L1 1...
Страница 180: ...Appendix A System Event Logging A 14 ATLAS 800PLUS User Manual 61200226L1 1...
Страница 184: ...Appendix B Troubleshooting B 4 ATLAS 800PLUS User Manual 61200226L1 1...
Страница 208: ...Index Index 14 ATLAS 800PLUS User Manual 61200226L1 1...
Страница 210: ......