Chapter 6. Terminal Menu and System Control
6-12
ATLAS 800
PLUS
User Manual
61200226L1-1
»» Active
Write security: 0; Read security: 5
Displays the number of users for each label that are currently logged into
the system.
» Bonding Config
Write security: 5; Read security: 5
Displays the configuration submenus available for the IMUX Nx56/64
modules. This configuration is shared among all IMUX modules.
»» TXINIT Timer
Write security: 3; Read security: 5
Specifies the length of time the originating endpoint attempts to detect the
BONDING negotiation pattern from the answering endpoint before decid-
ing the BONDING call has failed.
»» TXFA Timer
Write security: 3; Read security: 5
Specifies the length of time both endpoints attempt to detect the BONDING
frame pattern when a call is connected before deciding the BONDING call
has failed. When interoperating with other manufacturers' BONDING
equipment, it may be necessary to change this time so that it matches
TXADD01.
»» TXADD01 Timer
Write security: 3; Read security: 5
Specifies the length of time both endpoints wait for additional calls to be
connected at the end of negotiation before deciding that the BONDING call
has failed. The factory default setting is sufficient for most calls to connect,
although when dialing overseas it may be necessary to lengthen this timer
to allow for slower call routing.
»» TXDEQ Timer
Write security: 3; Read security: 5
Specifies the length of time both endpoints attempt to equalize the network
delay between the bearer channels before deciding the BONDING call has
failed.
»» TANULL Timer
Write security: 3; Read security: 5
Specifies the length of time the answering endpoint attempts to detect the
BONDING negotiation pattern from the originating endpoint before decid-
ing the BONDING call has failed. It may be necessary to shorten this timer
if the DTE equipment using the BONDING module also has timer con-
straints for completing non-BONDING parameter negotiation.
Instructions for Changing Passwords
Step
Action
1
Select the Password field—a new Password field displays.
2
Type the new password in the Enter field.
3
Type the new password again in the
Confirm field.
The password can contain up to 12 alphanumeric characters.
You can also use spaces and special characters in the
password.
Содержание Atlas 800 Plus
Страница 1: ...ATLAS 800PLUS User Manual Part Number 1200226L1 Part Number 1200228L1 61200226L1 1C May 2000...
Страница 12: ...xii...
Страница 26: ...List of Tables xxvi ATLAS 800PLUS User Manual 61200226L1 1...
Страница 34: ...Chapter 1 Introducing the ATLAS 800PLUS 1 8 ATLAS 800PLUS User Manual 61200226L1 1...
Страница 48: ...Chapter 3 Operating the ATLAS 800PLUS 3 6 ATLAS 800PLUS User Manual 61200226L1 1...
Страница 66: ...Chapter 5 Navigating the Terminal Menu 5 6 ATLAS 800PLUS User Manual 61200226L1 1...
Страница 94: ...Chapter 7 Modules Terminal Menu 7 8 ATLAS 800PLUS User Manual 61200226L1 1...
Страница 104: ...Chapter 8 Dedicated Maps Terminal Menu 8 10 ATLAS 800PLUS User Manual 61200226L1 1 Figure 8 5 Completed Dedicated Map...
Страница 112: ...Chapter 9 Dedicated Circuit Backup and Circuit Status 9 8 ATLAS 800PLUS User Manual 61200226L1 1...
Страница 180: ...Appendix A System Event Logging A 14 ATLAS 800PLUS User Manual 61200226L1 1...
Страница 184: ...Appendix B Troubleshooting B 4 ATLAS 800PLUS User Manual 61200226L1 1...
Страница 208: ...Index Index 14 ATLAS 800PLUS User Manual 61200226L1 1...
Страница 210: ......