![Adaptec 2060100 Скачать руководство пользователя страница 67](http://html1.mh-extra.com/html/adaptec/2060100/2060100_manual_2846396067.webp)
4-7
Using the SCSISelect Utility to Manage Arrays
5
From the Select RAID Member menu, press the Spacebar to
select the hard drives you want to use in the array. An
X
will
appear next to the drives you have selected.
Creating RAID 0 Arrays
To create a RAID 0 array:
1
From the Select RAID Type window, select RAID-0 and press
Enter
.
2
Select the hard drives you want to use and press Enter.
3
Select the stripe size and press Enter. You can select from 16K,
32K, or 64K (default). If a partition exists on any of the selected
drives, you will get a message that the partition will be deleted.
Adaptec SCSISelect(TM) Utility vX.XX
RAID-1 : Select RAID members
39320A at slot 03, 00:0F:00
<Arrow> move cursor, <Enter> accept option, <Esc> exit
Vendor
Product
Quantum
Quantum
Quantum
Quantum
ID
Size
00
01
02
03
XP32275W
XP32275W
XP32275W
XP32275W
2GB
2GB
2GB
2GB
X
X
<Space> select drive on SPARE
Adaptec SCSISelect(TM) Utility vX.XX
Vendor
Quantum
Quantum
ID
Product
Size
02
03
XP34550W
XP32070W
2GB
2GB
Create RAID
39320A at slot 03, 00:0F:00
<Arrow> move cursor, <Enter> accept option, <Esc> exit
Select RAID Type
Striping Requirements
Min 2 drives, Max 4 drives
RAID-0 (High Performance, No Fault Tolerance)
RAID-1 (Fault Tolerance)
RAID-10 (Fault Tolerance, High Performance)
U320 UG.book Page 7 Tuesday, September 23, 2003 1:47 PM