7. Further door opening function in Slave panels.
The slave unit features the so called a further door opening
function. In the master
panel, after opening the door and ending the conversation, or opening with a
unique code (or proximity card), downstream Slave unit automatically activate the
"waiting time” (marked with the key symbol on the display; the signal also activates
waiting time countdown). During this time, pressing the "
key
" button activates the
E-lock. This option is possible only in those slave units through which the
connection was made. When opening with a unique code (or proximity card), in
those units that must be passed to reach the apartment to which the opening code
(or card) is assigned. Standby mode can be cancelled with the "
#
" button. If bit 1
in P16 is set to ON, the E-lock will automatically engage after the pre-set delay
time has elapsed. The waiting time is set in P6 of each slave unit. The further door
opening pulse must be enabled (bit 4 in P16) in the master unit. For more
information, refer to the P6 and P16 program description - bit.1 and bit4. By default
this function is disabled.
8. Input from additional module.
For this unit door opening is also possible via an additional module such as: CDN
I-O, CDN ACC proximity card and key fob reader, or internal proximity key reader
(CDNP6ACC) built into the unit.
9. Automatic opening when calling
Automatic door opening after the first ringing tone. When the handset is not hung
up and this function is enabled, the door will open automatically after the first
ringing tone. If the handset was hung up during the first ringing tone, the unit works
normally - the handset can be picked up and communication is possible. This
function most commonly used in commercial buildings - letting people in is done
by simply lifting the handset; after business hours the handset is hung up and the
door entry unit works normally. For more information, refer to description of
additional numbers - P15 program.
When the E-lock is being opened the display shows "
Enter
” (for persons with
hearing impairment) and a signal is heard from the loudspeaker (for persons with
sight impairment).
The E-lock operation time and delay can be changed in P6 (by default it is 4
seconds without delay).