16
Avoid locations where the camera lens may be exposed to direct, perpendicular,
light (from the sun, street lamps, etc.).
The base plate for surface mounting of the unit is installed to the floor with
rawlplugs or appropriate screws. Install the flush-mounting frame of the unit in the
appropriate wall opening using rawlplugs and gypsum (wait for the gypsum to dry
before screwing the outside unit to the mounting frame). Lead the wires through
the holes in the frame.
Auxiliary holes around the frame are used
for makeshift installation with nails etc. when
mounting the unit in soft materials such as
polystyrene. These holes also help when
mounting the unit using mounting foam.
Upon completion of the installation the top
holes of the frame must be plugged (with
mounting foam or plaster). Then screw
evenly all screws of the housing to the frame
using a 3mm Allen wrench.
- CONNECTIONS
Connect the following wires to the unit:
•
2 wires x 1mm
2
- power supply to the transformer - for the Audio system or
power supply for the DC adapter (15VDC) of the Audio/Video system
•
1 wire in yellow green insulation - to connect the housing's grounding
•
2 wires x 0.75mm
2
- to E-lock,
•
2 wires x 0.5mm
2
of intercom cable to connect receivers - for Audio system
or
•
1 x UTP cable (min. cat 5e) - for the video system (the first master unit in
the system)
•
2 x UTP cable (min. cat 5e) - for the video system (further slave units in
the system)
Note!
all RJ45 plugs on UTP must be crimped in
T568B
standard.
Maximum lengths of signal cables (of the line or bus). The cross section
(resistance) of the bus for digital transmission and audio track (LINE terminals)
has a significant impact on the maximum bus length for both Audio and Video
systems. For typical cable cross sections (0.5mm) the maximum distance is 300
m. This distance increases with increasing wire cross section:
Содержание CDNP6ACC