42
Any number of slave units working in the Hotel mode and in zones.
The number of zones in the system can be set from 1 to 10. Their settings can be
programmed directly from the unit or using a PC.
Dialling method:
- Dialling the number requires entering the zone number (from 1 to 9, or 0 for
zone 10) and then apartment number (1 - 99). Two or three digits must be entered,
where the first digit always indicates the zone number.
Programming the unit.
The programming of the hotel mode settings can only be entered when the unit is
set to the Hotel mode - bit5 in P16 is enabled, and it is also necessary to enable
the positive offset - bit6 in P16 is must be enables (when the unit is in the Hotel
mode, settings in the P9 program cannot be changed and auxiliary numbers - P15
are not functional).
The parameters for selecting each zone are set separately in the program:
-
„
From
": first supported call number from 1 to 99
-
“
To
”
: the last supported call number from 1 to 99
-
“
Mov
": ringing number offset - the value of the offset determines for us the
difference between the dialled number in a zone (from the set range
“
From
”
„
To
” )
and the physical address set in the uniphone.
-
“
Nr1
”
or
“
Nr2
”: additional number
- enter the number (from 1 to 99) to be dialled from
keypad outside the range “
From
”
-
“
To
”.
*for CDNP5 bit2 = 1 in P16