51
To change the currently displayed setting, enter "1" to activate the function (bit) -
the display will briefly show "
1
" and the unit will move to the next parameter, or
enter "0" to deactivate the function (bit) - the display will show "
0
" and the unit will
move to the next parameter.
After the new value is entered, its confirmation by pressing the "
key
" button is
not necessary - the unit will save the change and automatically move to the next
bit.
When the parameters have been saved correctly, "
Gotowe
" will appear on the
display.
Description of individual parameters (square brackets show captions displayed
on the unit display):
Bit1.- Selecting the image preview camera in standby [1VidS]
The setting of this bit determines which camera is used for image preview in
standby (when no call is in progress):
- master unit camera, if Bit1 = 0
- slave unit camera, if Bit1 = 1,
Set this bit only in one of the slave units.
During a call, the image is always transmitted from the camera of the unit from
which the call originates.
Bit2.- Abbreviated (four-digit) ad
ministrator’s access code [24Key]
When this bit is enabled, the six-
digit administrator’s access code (programmed
in P1) is abbreviated to the first four digits.
Bit3.-
Doorman’s call [3RPor]
Enables doorman's call - refer to Chapter XI.
Bit4.- Doorman's call forward [4CPor]
Enables doorman's call forward in a slave unit - refer to Chapter XI.
Bit5.- Calling additional numbers only [5OnlR]
When this bit is enabled, it is not possible to call to or open the door using
additional numbers; auto-opening is disabled.
Bit6.- Disabling apartment number display in 230E module (from v4.1)
[6NoNo]
When this bit is enabled apartment number will not be displayed in 230E module.
Any number can then be entered next to the name.
Bit7.- CDNP6 only: Interface with reversible E-lock [7ReEl]
This bit enables unit interface with reversible E-lock.
Bit8.- Interface with Multimaster module (CDN-MM) [8 MM]
The bit enables unit interface with Multimaster module. The module is used to
connect up to 5 master units (for instance on main entrances) in a single point
(star connection) in order to shorten the installation length. Refer to at
www.aco.com.pl.
for detailed information.
By default, all bits are disabled.